Breaker Arcing Current Commands (Read/Write Command); Hi-Z (High Impedance Fault Detection) Commands; Hi-Z (High Impedance Fault Detection) Status (Read Only); Hi-Z (High Impedance Fault Detection) Records (Read Only) - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (2, 4, or 6 Modules)
C60, D60, F35,
21FA
...Repeated for Breaker 3
L90, T35, T60
"
21FE
...Repeated for Breaker 4
F35, T35
2208
...Repeated for Breaker 5
"
2212
...Repeated for Breaker 6
Bus Actuals (Read Only) (6 Modules)
B90
2208
...Repeated for Bus Zone 5
"
2212
...Repeated for Bus Zone 6
Breaker Arcing Current Commands (Read/Write Command) (2, 4, or 6 Modules)
C60, D30, D60,
2224
Breaker 1 Arcing Current Clear Command
F35, F60, L30,
L60, L90, T35,
T60
"
2225
Breaker 2 Arcing Current Clear Command
C60, D60, F35,
2226
Breaker 3 Arcing Current Clear Command
L90, T35, T60
"
2227
Breaker 4 Arcing Current Clear Command
F35, T35
2228
Breaker 5 Arcing Current Clear Command
"
2229
Breaker 6 Arcing Current Clear Command
Passwords Unauthorized Access (Read/Write Command)
All
2230
Reset Unauthorized Access
Hi-Z (High Impedance Fault Detection) Commands (Read/Write Command)
F60
2240
Hi-Z Clear Oscillography
"
2241
Hi-Z Oscillography Force Trigger
"
2242
Hi-Z Oscillography Force Algorithm Capture 0 to 1
"
2243
Hi-Z Reset Sigma Values

Hi-Z (High Impedance Fault Detection) Status (Read Only)

F60
2250
Hi-Z Status
"
2251
Hi-Z Phase A Arc Confidence
"
2252
Hi-Z Phase B Arc Confidence
"
2253
Hi-Z Phase C Arc Confidence
"
2254
Hi-Z Neutral Arc Confidence
Hi-Z (High Impedance Fault Detection) Records (Read Only) (4 Modules)
F60
2260
Hi-Z Capture 1 Trigger Type
"
2261
Hi-Z Capture 1 Time
"
2263
...Repeated for Hi-Z Capture 2
"
2266
...Repeated for Hi-Z Capture 3
"
2269
...Repeated for Hi-Z Capture 4
Hi-Z (High Impedance Fault Detection) RMS Records (Read Only) (4 Modules)
F60
2270
Hi-Z RMS Capture 1 Trigger Type
"
2271
Hi-Z RMS Capture 1 Time
"
2273
...Repeated for Hi-Z RMS Capture 2
"
2276
...Repeated for Hi-Z RMS Capture 3
"
2279
...Repeated for Hi-Z RMS Capture 4
Source Current THD (Read Only) (6 Modules)
L60
22A0
Source 1 Ia THD
"
22A1
Source 1 Ib THD
UR SERIES – COMMUNICATIONS GUIDE
Range
Units
Step
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
---
1
0 to 1
---
1
0 to 9
---
1
0 to 100
---
1
0 to 100
---
1
0 to 100
---
1
0 to 100
---
1
0 to 6
---
1
0 to 1
---
1
0 to 6
---
1
0 to 1
---
1
0 to 100
%
0.1
0 to 100
%
0.1
MEMORY MAP
Format
Default
F126
0 (No)
F126
0 (No)
F126
0 (No)
F126
0 (No)
F126
0 (No)
F126
0 (No)
F126
0 (No)
F126
0 (No)
F126
0 (No)
F126
0 (No)
F126
0 (No)
F187
0 (NORMAL)
F001
0
F001
0
F001
0
F001
0
F188
0 (NONE)
F050
0
F188
0 (NONE)
F050
0
F001
0
F001
0
2-29
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents