Breaker Restrike (Read/Write Setting) (1, 2, Or 3 Modules); Teleprotection Inputs/Outputs Commands (Read/Write Command); Teleprotection Inputs/Outputs (Read/Write Settings); Teleprotection Channel Tests (Read Only) - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

MEMORY MAP
Products
Address Register name
"
991A
"
991C
"
991E

Breaker Restrike (Read/Write Setting) (1, 2, or 3 Modules)

2
C60, C70, D60,
9930
F35, F60, L90,
T60
"
9931
"
9933
"
9934
"
9935
"
9936
"
9937
"
9939
"
993B
"
993D
"
993E
"
993F
C60, C70, D60,
9941
F35, L90, T60
C70, F35, T60
9952

Teleprotection Inputs/Outputs Commands (Read/Write Command)

All except B90,
9980
C70, L30, L90

Teleprotection Inputs/Outputs (Read/Write Settings)

All except B90,
9990
C70, L30, L90
"
9991
"
9992
"
9993
"
9994
"
9995
"
9996
"
9A00
"
9A10
"
9A20
"
9A40

Teleprotection Channel Tests (Read Only)

All except B90,
9AA0
C70, L30, L90
"
9AA1
"
9AA2
"
9AA3
2-122
FlexElement 14 Actual
FlexElement 15 Actual
FlexElement 16 Actual
Breaker Restrike 1 Function
Breaker Restrike 1 Block
Breaker Restrike 1 Signal Source
Breaker Restrike 1 Pickup
Breaker Restrike 1 Reset Delay
Breaker Restrike 1 HF Detect
Breaker Restrike 1 Breaker Open
Breaker Restrike 1 Open Command
Breaker Restrike 1 Close Command
Breaker Restrike 1 Target
Breaker Restrike 1 Events
Reserved (2 items)
...Repeated for Breaker Restrike 2
...Repeated for Breaker Restrike 3
Teleprotection Clear Lost Packets
Teleprotection Function
Teleprotection Number of Terminals
Teleprotection Number of Channels
Teleprotection Local Relay ID
Teleprotection Terminal 1 ID
Teleprotection Terminal 2 ID
Reserved (10 items)
Teleprotection Input 1-n Default States (16
items)
Teleprotection Input 2-n Default States (16
items)
Teleprotection Output 1-n Operand (16
items)
Teleprotection Output 2-n Operand (16
items)
Teleprotection Channel 1 Status
Teleprotection Channel 1 Number of Lost
Packets
Teleprotection Channel 2 Status
Teleprotection Channel 2 Number of Lost
Packets
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
-2147483.647 to
---
0.001 F004
2147483.647
-2147483.647 to
---
0.001 F004
2147483.647
-2147483.647 to
---
0.001 F004
2147483.647
0 to 1
---
1
0 to 4294967295
---
1
0 to 5
---
1
0.10 to 2.00
pu
0.01
0 to 65.535
s
0.001 F001
0 to 1
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
---
---
---
0 to 1
---
1
0 to 1
---
1
2 to 3
---
1
1 to 2
---
1
0 to 255
---
1
0 to 255
---
1
0 to 255
---
1
0 to 1
---
1
0 to 3
---
1
0 to 3
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 2
---
1
0 to 65535
---
1
0 to 2
---
1
0 to 65535
---
1
UR SERIES – COMMUNICATIONS GUIDE
Format
Default
0
0
0
F102
0 (Disabled)
F300
0
F167
0 (SRC 1)
F001
50
100
F102
1 (Enabled)
F300
0
F300
0
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F002
0
F126
0 (No)
F102
0 (Disabled)
F001
2
F001
1
F001
0
F001
0
F001
0
F001
0
F086
0 (Off)
F086
0 (Off)
F300
0
F300
0
F134
1 (OK)
F001
0
F134
2 (n/a)
F001
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents