MEMORY MAP
Products
Address Register name
"
1520
"
1528
"
1530

RxGOOSE Input/Output States (Read Only)

All
1540
"
1542
2
"
1550
"
1551
"
1552
"
1553
"
1554
"
1555

Direct Input/Output States (Read Only)

L30, L90
15A0
"
15A8
"
15B0
"
15B1

Platform Direct Input/Output States (Read Only)

All except L30,
15C0
L90
"
15C8
"
15C9
"
15CA
"
15CB
"
15D0
"
15D1
"
15D2
"
15D3

Field Unit Input/Output States (Read Only)

All except B90,
15E0
L60
"
15E3
"
15EB
"
15F3
"
15FB
"
1603
"
1604
"
1605
"
1606
"
1607
"
1608
2-20
Contact Output Voltage States (4 items)
Virtual Output States (6 items)
Contact Output Detectors (4 items)
Remote Device x States (2 items)
RxGOOSE Boolean x States (8 items)
Remote Devices Online
RxGOOSE Double-Point Status Input 1 State 0 to 4
RxGOOSE Double-Point Status Input 2 State 0 to 4
RxGOOSE Double-Point Status Input 3 State 0 to 4
RxGOOSE Double-Point Status Input 4 State 0 to 4
RxGOOSE Double-Point Status Input 5 State 0 to 4
Direct Input 1-1 State (8 items)
Direct Input 1-2 State (8 items)
Direct Input 1 State
Direct Input 2 State
Direct Input States (6 items)
Direct Outputs Average Message Return
Time 1
Direct Outputs Average Message Return
Time 2
Direct Inputs/Outputs Unreturned Message
Count - Ch. 1
Direct Inputs/Outputs Unreturned Message
Count - Ch. 2
Direct Device States
Reserved
Direct Inputs/Outputs CRC Fail Count 1
Direct Inputs/Outputs CRC Fail Count 2
Field Unit Contact Input States (3 items)
Field Unit Contact Input Output Operand
States (8 items)
Field Contact Output Physical States (8
items)
Field Contact Output Current States (8
items)
Field Contact Output Physical States (8
items)
Field Shared Input States
Field Shared Input Channel States
Field Shared Input Test States
Field Shared Output Operand States
Field Latching Output Open Operand
States
Field Latching Output Close Operand
States
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 1
---
1
---
1
---
1
---
1
---
1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
ms
1
0 to 65535
ms
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
UR SERIES – COMMUNICATIONS GUIDE
Format
Default
F500
0
F500
0
F500
0
F500
0
F500
0
F126
0 (No)
F605
3 (bad-state)
F605
3 (bad-state)
F605
3 (bad-state)
F605
3 (bad-state)
F605
3 (bad-state)
F108
0 (Off)
F108
0 (Off)
F500
0
F500
0
F500
0
F001
0
F001
0
F001
0
F001
0
F500
0
F001
0
F001
0
F001
0
F500
0
F500
0
F500
0
F500
0
F500
0
F500
0
F500
0
F500
0
F500
0
F500
0
F500
0

Hide quick links: