No.
Name
0: Disabled. Drive runs at a set frequency. A
heavy load may cause speed loss.
Stall
1: Decel time 1. Uses the deceleration
Prevention
time set to C1-02 while Stall Prevention is
L3-05
Selection
performed.
during Run
2: Decel time 2. Uses the deceleration time
set to C1-04 while Stall Prevention is
performed.
Stall
Prevention
Enabled when L3-05 is set to 1 or 2. 100%
L3-06
Level during
is equal to the drive rated current.
Run
Induction Motor Auto-Tuning
0: Rotational Auto-Tuning
1: Stationary Auto-Tuning 1
2: Stationary Auto-Tuning for Line-to-Line
Resistance
3: Rotational Auto-Tuning for V/f Control
Auto-Tuning
(necessary for Energy Savings and Speed
T1-01
Mode
Estimation Speed Search)
Selection
4: Stationary Auto-Tuning 2
8: Inertia Tuning (perform Rotational Auto-
Tuning prior to Inertia Tuning)
9: ASR Gain Tuning (perform Rotational
Auto-Tuning prior to ASR Gain Auto-
Tuning)
Motor Rated
Sets the motor rated power as specified on
T1-02
Power
the motor nameplate.
Motor Rated
Sets the motor rated voltage as specified on
T1-03
Voltage
the motor nameplate.
Motor Rated
Sets the motor rated current as specified on
T1-04
Current
the motor nameplate.
Motor Base
Sets the rated frequency of the motor as
T1-05
Frequency
specified on the motor nameplate.
Number of
Sets the number of motor poles as specified
T1-06
Motor Poles
on the motor nameplate.
Motor Base
Sets the rated speed of the motor as
T1-07
Speed
specified on the motor nameplate.
PG Number of
Set the number of pulses per revolution for
T1-08
Pulses Per
the PG being used (pulse generator or
Revolution
encoder).
Sets the no-load current for the motor.
After setting the motor capacity to T1-02
Motor No-
and the motor rated current to T1-04, this
Load Current
T1-09
parameter will automatically display the no-
(Stationary
load current for a standard 4 pole Yaskawa
Auto-Tuning)
motor. Enter the no-load current as
indicated on the motor test report.
Sets the motor rated slip.
Motor Rated
After setting the motor capacity to T1-02,
Slip
this parameter will automatically display the
T1-10
(Stationary
motor slip for a standard 4 pole Yaskawa
Auto-Tuning)
motor. Enter the motor slip as indicated on
the motor test report.
Sets the iron loss for determining the
Energy Saving coefficient.
Motor Iron
The value is set to E2-10 (motor iron loss)
T1-11
Loss
set when the power is cycled. If T1-02 is
changed, a default value appropriate for the
motor capacity that was entered will appear.
YASKAWA ELECTRIC TOEP C710616 27D YASKAWA AC Drive - A1000 Quick Start Guide
Description
Monitor
U1-01
Frequency Reference (Hz)
U1-02
Output Frequency (Hz)
U1-03
Output Current (A)
U1-05
Motor Speed (Hz)
U1-06
Output Voltage Reference (Vac)
U1-07
DC Bus Voltage (Vdc)
U1-08
Output Power (kW)
U1-09
Torque Reference (% of motor rated torque)
Displays the input terminal status.
U1 - 10=
0 0 0 0 0 0 0 0
U1-10
Displays the output terminal status.
U1 - 11=
0 0 0 0 0 0 0 0
U1-11
Verifies the drive operation status.
U1 - 12=
0 0 0 0 0 0 0 0
U1-12
U1-13
Terminal A1 Input Level
U1-14
Terminal A2 Input Level
U1-15
Terminal A3 Input Level
U1-16
Output Frequency after Soft Starter
U1-18
oPE Fault Parameter
U1-24
Input Pulse Monitor
Fault Trace
U2-01
Current Fault
U2-02
Previous Fault
U2-03
Frequency Reference at Previous Fault
U2-04
Output Frequency at Previous Fault
6 Parameter Table
Description
1
Digital input 1
(terminal S1 enabled)
1
Digital input 2
(terminal S2 enabled)
1
Digital input 3
(terminal S3 enabled)
1
Digital input 4
(terminal S4 enabled)
1
Digital input 5
(terminal S5 enabled)
1
Digital input 6
(terminal S6 enabled)
1
Digital input 7
(terminal S7 enabled)
1
Digital input 8
(terminal S8 enabled)
1
Multi-Function
Digital Output
(terminal M1-M2)
1
Multi-Function
Digital Output
(terminal M3-M4)
1
Multi-Function
Digital Output
(terminal M5-M6)
Not Used
1
Fault Relay
(terminal MA-MC closed
MA-MC open)
1
During run
1
During zero-speed
1
During REV
1
During fault reset
signal input
1
During speed agree
1
Drive ready
1
During alarm
detection
1
During fault detection
29