Interlogix XTI-5 Installation Manual page 56

Hide thumbs Also See for XTI-5:
Table of Contents

Advertisement

Function
Default
Auto phone test
Off
Supervisory time
12:00am
Alarm cancel
006 minutes
RF time-out
12 hours
Fail-to-open time
Off
Fail-to-close time
Off
Siren time-out
005 minutes
Unvacated
On
premises
50
Description
Determines whether the panel automatically performs a
periodic phone test (on), or not (off). The test interval can be
from 001 to 254 days. The time of day the panel performs
the test is determined by the supervisory time, which must
be turned on for this feature to work.
Determines when the panel reports supervisory conditions
(sensor failures) and automatic phone tests to the central
station. The panel clock must be set to the correct time for
this option and the automatic phone test to work correctly.
Sets the time frame that determines whether the panel
reports an alarm cancel message to the central station. If
the system is disarmed from an alarm state within the
programmed time, the panel sends an alarm cancel
message to the central station. An alarm cancel message is
not reported if the system is disarmed after the programmed
time expires.
The time can be set from 006 to 255 minutes. When set to
255, the panel always reports alarm cancel messages.
Turning off this option disables alarm cancel reporting.
Determines the period during which the panel must receive
at least one supervisory signal from learned sensors before
identifying a sensor failure and sounding trouble beeps. Any
sensor failure is reported immediately and again at the
supervisory time. The timeout can be set from 02 to 36
hours. Entries must be two digits.
Determines whether the panel sends a fail-to-open report to
a central station if the system has not been disarmed by the
programmed time (on), or not (off). System time must be set
correctly for this feature to work.
Determines whether the panel sends a fail-to-close report to
a central station if the system has not been armed by the
programmed time (on), or not (off). System time must be set
correctly for this feature to work.
Determines how long sirens sound alarms if no one is
present to disarm the system. The time can be set from 002
to 254 minutes. When this feature is turned off, sirens
sound alarms until the alarm is canceled (system disarmed).
Unvacated premises is a feature that determines whether
the system automatically arms down to level 2 (doors and
windows) if you arm the system to level 4 (doors, windows,
and motion sensors) without opening or closing a perimeter
door (on), or remains at the armed level chosen (off). This
feature does not work from a key fob. Autoarm must be on
for this feature to work.
Simon XTi-5 Installation Manual
Contents