Sc 6Xx (Communication And Other Error) - Ricoh M116 Service Manual

Table of Contents

Advertisement

Service Call Conditions

SC 6xx (Communication and Other Error)

EEPROM communication error
An unexpected value exists in the initialization flag of the EEPROM
669
EEPROM not connected
Defective EEPROM
1.
Installing the EEPROM.
2.
Replacing the EEPROM.
CTL_PRREQ_N signal does not come.
The ECB does not receive a memory address command from the controller 20
seconds after paper is in the position for registration.
688
Defective controller board
Communication error
1.
Turn the machine's main power off, and then on.
2.
Check if the controller board is firmly connected to the ECB.
M116/M117
6-8
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

M117

Table of Contents