IMAGE FUSING AND PAPER EXIT
Fusing Idling Temperature
If copies are not sufficiently fused soon after the main power switch is turned on,
fusing idling should be enabled with SP1-103-1. When fusing idling is enabled, it is
done when the temperature reaches the value of the re-load temperature. The re-
load temperature can be adjusted with SP1-105-5, 6.
In the opposite case, even if fusing idling is disabled, it is done when the
temperature at power-up ≤ 15°C
The fusing idling time is as follows.
Temperature at
power-on
15°C or less
Higher than 15°C
6.15.9 OVERHEAT PROTECTION
If the hot roller temperature becomes greater than 250°C, the CPU cuts off the
power to the fusing lamp, and SC543 Fusing Overheat Error will be displayed.
Even if the thermistor overheat protection fails, there is a thermostat in series with
the common ground line of the fusing lamp. If the temperature of the thermostat
⇒
reaches 180°C, the thermostat opens, removing power from the fusing lamp. At the
same time, the copier stops operating. At this time, SC542 Fusing Temperature
Warm-up Error will be displayed.
B003/B004/B06/B007
CÓPIA NÃO CONTROLADA
Fusing Idling Mode
0: Disabled
1: Enabled
30 s
Not done
6-80
CÓPIA NÃO CONTROLADA
SP1-103-1
30 s
SP1-103-2
30 s
Rev. 09/2002
SM