Ncs (Nib) - Ricoh B003 Service Manual

Hide thumbs Also See for B003:
Table of Contents

Advertisement

Firmware History for B003/B004/B006/B007

NCS (NIB):

Change in Specification:
1. TCP ports can be opened/closed.
NOTE:
After making the setting to disable HTTP, you cannot access the target device
through web browser. If you want to change the setting, please use telnet to open
HTTP.
When telnet port is disabled, you have to clear the network settings (Memory Clear
for NCS) to open the telnet port.
2. Changed the default setting of DHCP to ON.
NOTE:
There is no change when updating the firmware. This feature is for the factory
default.
The following items have been fixed:
3. The controller freezes if disconnected while data containing the Readback command is
being printed out with ftp/rsh.
4. Display corrected for when the operator tries to execute Spool Printing Job List with
SmartNetMonitor for Admin on the B003/B004/B006/B007 and B022/B027:
Previous: "Spool printing is not available. Active spool printing from the device or related
software"
New: "Error 404"
5. The Fax Management Tool cannot be used while any of the NIB setting(s) are being
changed.
6. The parameters of sysLocation and sysContact cannot be set correctly using the snmp
command with telnet.
7. The controller freezes when a non-existent file is specified for rcp transmission.
8. Cannot connect to Novel NDS:
The nearest NetWare Server informs the NIB of the alternate NetWare Server address,
where the NDS replica is stored, however the NIB is unable to interpret the message.
Change in Specification:
1.
SNMP vulnerability
SNMP security vulnerabilities reported by CERT on Feb.12, 2002 has been tested using
the PROTOS c06-snmpv1 test suite and we have verified the fixes.
-CERT: http://www.cert.org/advisories/CA-2002-03.html
-PROTOS c06-snmpv1 test suite
: http://www.ee.oulu.fi/research/ouspg/protos/testing/c06/snmpv1/
2.
Some reserved (unused) TCP ports that were open have been closed, e.g. FTP.
Firmware modified to correct the following:
1. No error message is displayed in Netscape Navigator even when an incorrect URL is
input in the address bar.
2. Up to 32 characters can be input in the NetBEUI configuration screen Comment box,
even though specification is 31 characters maximum.
3. The PS status cannot be displayed using the "stat" command (lpq command for lpr).
4. If Trap is selected for the Access Type in the SNMP Configuration screen during the
snmpd process, communication may be cut off.
5. The NIB does not respond to the "lprm –" command (root directory) from a FreeBSD host
computer.
6. If an undefined remote printer number is input in the Netware configuration page,
communication between the NIB and Netware Server will be cut off.
Change in Specification:
7. Two or more print queues can be attached to a single printer object.
8. TCP Ports 11021 and 11023 (Design use) have been closed.