Shutting Down The Node In A Stand-Alone System - IBM N6270 Hardware And Service Manual

N6200 series system storage
Table of Contents

Advertisement

3. Take over the target node by entering one of the following commands from the
partner node's console:
For...
7-Mode
Clustered Data ONTAP

Shutting down the node in a stand-alone system

For a node that is in a stand-alone configuration, you must perform a clean
shutdown to ensure that all data has been written to disk and disconnect the
power supplies.
Procedure
1. Enter the following commands from the system console:
If your system is configured in...
7-Mode
Clustered Data ONTAP
After you issue the command, wait until the system stops at the LOADER
prompt.
Attention: You must perform a clean system shutdown before replacing
system components to avoid losing unwritten data in the nonvolatile memory
(NVMEM). The NVMEM LED is located on the controller module to the right
of the network ports, marked with a battery symbol. If the NVMEM LED is
flashing, there is content in the NVMEM that has not been saved to disk. You
need to reboot the controller module and proceed from the beginning of this
procedure. If repeated attempts to cleanly shut down the controller module fail,
be aware that you might lose any data that was not saved to disk.
0a
LNK
Figure 26. NVMEM LED
NVMEM LED
1
2. If you are not already grounded, properly ground yourself.
3. Turn off the power supplies, unplug the power cords from the power source,
and remove the power cords.
Issue the command...
cf takeover
storage failover takeover -bynode node
Then issue this command...
halt
halt local
c0a
0c
0b
LNK
c0b
0d
e0a
e0b
Replacing N6200 series system devices
1
53