Resetting The Date And Time On The System - IBM N6270 Hardware And Service Manual

N6200 series system storage
Table of Contents

Advertisement

If the system-level diagnostics tests...
Resulted in some test failures

Resetting the date and time on the system

After you reconnect the battery and reboot Data ONTAP, you must reset the date
and time on the system.
Procedure
1. Display the current date on the node or nodes by entering the following
command:
For...
7-Mode
Clustered Data ONTAP
2. Set the date by entering the following command:
Then...
Determine the cause of the problem.
1. Exit Maintenance mode by entering the
following command:
halt
2. Perform a clean shutdown and
disconnect the power supplies.
3. Verify that you have observed all the
considerations identified for running
system-level diagnostics, that cables are
securely connected, and that hardware
components are properly installed in the
storage system.
4. Reconnect the power supplies and power
on the storage system.
5. Rerun the system-level diagnostics tests.
Issue the command...
date
Note: If your system is in an HA pair ,
make sure that you display the date and
time on the partner node and set the target
node to those values.
system date show
Note: Make sure that you display the date
and time on the other nodes in the cluster
and set the target node to those values.
Replacing N6200 series system devices