Configuring And Using The Service Processor; Service Processor Manuals - IBM N6270 Hardware And Service Manual

N6200 series system storage
Table of Contents

Advertisement

Procedure
1. Set the specified onboard ports to operate in initiator mode by entering the
2. Reboot the system by entering the following command:
3. Verify that the Fibre Channel ports are online and configured in the correct
Results
For information on converting the onboard ports to target mode and configuring
your SAN, see the IBM System Storage N series Data ONTAP Block Access
Management Guide or IBM System Storage N series Data ONTAP SAN Administration
Guide for your version of Data ONTAP. This guide, as well as other Data ONTAP
publications, is available on the IBM N series support website, which is accessed
and navigated as described in "Websites" on page xxii.

Configuring and using the Service Processor

The Service Processor (SP) enables you to remotely access, monitor, and
troubleshoot N6200 series systems.
The following table provides a list of documents for configuring and using the
Service Processor. These documents are available on the IBM N series support
website, which is accessed and navigated as described in "Websites" on page xxii.
22
IBM System Storage: N6200 Series Hardware and Service Guide
following command:
fcadmin config -t initiator adapter
where adapter is the port number. You can specify more than one port.
Example: The following example sets onboard ports 0c and 0d to initiator
mode.
fcadmin config -t initiator 0c 0d
reboot
state for your configuration by entering the following command:
fcadmin config
Example: The following output example shows two ports configured as Fibre
Channel targets and two ports configured as initiators.
n6000a> fcadmin config
Local
Adapter Type
State
---------------------------------------------------
0a
target
CONFIGURED
0b
target
CONFIGURED
0c
initiator CONFIGURED
0d
initiator CONFIGURED
Table 13. Service Processor manuals
Manual Title
IBM System Storage N series System-Level
Diagnostics Guide
Data ONTAP System Administration Guide for
your version of Data ONTAP
IBM System Storage N series Platform
Monitoring Guide
Status
online
online
online
online
Information Provided
Lists and describes the diagnostic tests for
the Service Processor.
Describes Service Processor cabling,
configuration and use.
Lists Service Processor error messages and
gives corrective actions for the error.