8. Verify that no hardware problems resulted from the addition or replacement of
9. Proceed based on the result of the preceding step.
50
IBM System Storage: N6200 Series Hardware and Service Guide
*> <SLDIAG:_ALL_TESTS_COMPLETED>
hardware components on your system by entering the following command:
sldiag device status [-dev devtype] [-name device] -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures,
or lists the full status of failures resulting from testing the component.
If the system-level diagnostics tests...
Were completed without any failures
Then...
1. Clear the status logs by entering the
following command:
sldiag device clearstatus
2. Verify that the log is cleared by entering
the following command:
sldiag device status
The following default response is
displayed:
SLDIAG: No log messages are present.
3. Exit Maintenance mode by entering the
following command:
halt
4. Enter the following command at the
firmware prompt to reboot the storage
system:
boot
5. If your system is in an HA pair, enter the
cf giveback command (7-Mode) or
storage failover giveback command
(Clustered Data ONTAP) from the
partner node console.
You have completed system-level
diagnostics.