10. Reinstall the cable management arms and recable the system, as needed.
11. Push the controller module all the way into the system, firmly pushing the
12. The next step depends on your system configuration:
13. Set up the TFTP server on the partner node by entering the following
14. Enter one of the following commands at the firmware prompt:
15. At the firmware prompt, enter the following command: netboot
16. Select the Install new software first option from the displayed menu. This
17. Enter y when you see the following prompt:
70
IBM System Storage: N6200 Series Hardware and Service Guide
8. Close the boot device cover.
9. Align the end of the controller module with the opening in the chassis, and
then gently push the controller module halfway into the system.
When recabling, remember to reinstall the media converters (SFPs) if you are
using fiber cables.
cam handle to finish seating it, push the cam handle to the closed position
and then tighten the thumbscrew. The node reboots and stops at the firmware
prompt as soon as you seat the controller module completely into the system.
If your system has...
One controller module in the chassis
Two controller modules in the chassis
commands on the partner node console:
a. partner options tftpd.enable off
b. partner options tftpd.rootdir /etc
c. partner options tftpd.enable on
v If you are configuring DHCP, enter the following command: ifconfig e0a
-auto
v If you are configuring manual connections, enter the following command:
ifconfig e0a -addr=filer_addr -mask=netmask -gw=gateway -dns=dns_addr
-domain=dns_domain
filer_addr is the IP address of the storage system.
netmask is the network mask of the storage system.
gateway is the gateway for the storage system.
dns_addr is the IP address of a name server on your network.
dns_domain is the Domain Name System (DNS) domain name. If you use this
optional parameter, you do not need a fully qualified domain name in the
netboot server URL; you need only the server's host name.
Note: To netboot the node when your system is running in 7-Mode, use an IP
address that is not the management IP address for the target.
Note: Other parameters might be necessary for your interface. Enter help
ifconfig at the firmware prompt for details.
http://path_to_web-accessible_directory/netboot/kernel
menu option downloads and installs the new Data ONTAP image to the boot
device. If you are prompted to continue the procedure, enter y when
prompted.
Then...
Reconnect the power cables to the power
supplies and to the power sources, and then
turn on the power.
The node already began rebooting; go to the
next step.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

N6240N6220N6250N6210

Table of Contents