Completing The Replacement Process; Disposing Of Batteries - IBM N6270 Hardware And Service Manual

N6200 series system storage
Table of Contents

Advertisement

If the system-level diagnostics tests...
Were completed without any failures
Resulted in some test failures

Completing the replacement process

Return the failed part to IBM. Contact IBM Service and Support at 1-800-IBM-SERV
(1-800-426-7378) for more information on the return procedure.

Disposing of batteries

Dispose of batteries according to local regulations regarding battery recycling or
disposal.
Then...
1. Clear the status logs by entering the
following command:
sldiag device clearstatus
2. Verify that the log is cleared by entering
the following command:
sldiag device status
The following default response is
displayed:
SLDIAG: No log messages are present.
3. Exit Maintenance mode by entering the
following command:
halt
4. Enter the following command at the
firmware prompt to reboot the storage
system:
boot
5. If your system is in an HA pair , run the
cf giveback command (Data ONTAP
7-Mode) or the storage failover
giveback command (Clustered Data
ONTAP) from the partner node console.
You have completed system-level
diagnostics.
Determine the cause of the problem.
1. Exit Maintenance mode by entering the
following command:
halt
2. Perform a clean shutdown and
disconnect the power supplies.
3. Verify that you have observed all the
considerations identified for running
system-level diagnostics, that cables are
securely connected, and that hardware
components are properly installed in the
storage system.
4. Reconnect the power supplies and power
on the storage system.
5. Rerun the system-level diagnostics tests.