Figure 45. Placement of the power supply in the B16S

Removing an AC power supply

The procedures for removing an AC power supply differ depending on the power
supply type (replacement or original). Be sure to refer to the appropriate procedures
in this section. For the differences between replacement and original power
supplies, see "About replacement power supplies" on page 21.
CAUTION:
The power supplies are hot swappable, which means they can be removed
and replaced while the chassis is powered on and running. However, IBM
recommends that you disconnect the power supply from the wall outlet
before removing and replacing the supply. The chassis can be running while
a power supply is being removed and replaced, but the power supply itself
should not be connected to a power source. Otherwise, you could be injured
or the power supply or other parts of the device could be damaged.
Note: Disabling or removing a POE power supply also disables the POE daughter

Removing a replacement power supply

To remove a replacement AC power supply, you need a Phillips-head or a flathead
screwdriver.
Figure 46. Replacement AC power supply
To remove a replacement AC power supply, do the following:
1. Disconnect the power supply's power cord from the wall outlet.
108
Ethernet Switch s-series Installation and User Guide
SYS (12V) Power Supplies
in Slot 1 and Slot 2
1
2
EJE CT SYS
AC OK DC OK ALM
AC OK DC OK ALM
EJE CT POE
AC OK DC OK ALM
AC OK DC OK ALM
5
6
POE Power Supplies
card and associated POE ports.
Redundant 12V Power Supplies
in Slot 3 andSlot 4
3
EJE CT SYS
EJE CT SYS
AC OK DC OK ALM
EJE CT POE
EJE CT POE
AC OK DC OK ALM
7
in Slots 5 - 8
4
EJE CT SYS
AC OK DC OK ALM
EJE CT POE
AC OK DC OK ALM
8