IBM s-series Installation And User Manual page 69

Table of Contents

Advertisement

F2: SX-FISF Switch Fabric active
S1: SX-F424C 24-port Gig Copper OK 24 00e0.beef.0000
S2: SX-F424C 24-port Gig Copper OK 24 00e0.beef.0000
S3: SX-F42XGW 2-port 10G LAN/WAN OK 2 00e0.beef.0030
S4: SX-F424C 24-port Gig Copper OK 24 00e0.beef.0048
S5: SX-F42XGW 2-port 10G LAN/WAN OK 2 00e0.beef.0060
S6: SX-F424C 24-port Gig Copper OK 24 00e0.beef.0078
S7: SX-F424C 24-port Gig Copper OK 24 00e0.beef.0090
S8: SX-F424F 24-port Gig Fiber OK 24 00e0.beef.00a8
S9: SX-FIZMR4 0-port Management Active 0
{ Status : OK }
S10: SX-FIZMR4 0-port Management Standby 0
{ Status : Absent }
Syntax: show module
The Status column shows the module status. The status can be one of the
following:
v OK - The module is up and running
v ACTIVE - This applies to the B08S and B16S management and switch fabric
modules only. This indicates that the module is the active module as opposed to
the standby module.
v STANDBY - This applies to the B08S and B16S management and switch fabric
modules only. This indicates that the module is the standby module as opposed
to the active module.
v FAILED - The management module was unable to bring up an interface module
properly. If you observe this status, make certain that the interface module is
installed properly. For more information, see "Installing the management and
interface modules" on page 33.
v DISABLED - The module is not up and running
Chapter 3. Installing the Chassis
43