Installing Or Replacing A Power Supply Module; Removing An Ac Power Supply Module - IBM RackSwitch G8264T Installation Manual

System networking rackswitch
Hide thumbs Also See for RackSwitch G8264T:
Table of Contents

Advertisement

Installing or replacing a power supply module

© Copyright IBM Corp. 2012
DANGER
Multiple power cords. The product might be equipped with multiple power
cords. To remove all hazardous voltages, disconnect all power cords.
(L003)
1
2
The RackSwitch G8264T operates with either one or two active power supply
modules. Each hot-swap power supply module can be replaced by the customer
without powering off the switch or disrupting switch functions.
Each AC power supply module has a power cord for connection to an AC power
outlet.
Each power supply module has three LEDs that are visible from the rear panel. The
following table describes the LED indications:
Table 13. Power Supply Module LEDs
LED Status
OK
Green
Off
Service ( ! )
Amber
Off
~ AC Input
Green
Off
Description
DC output power is present.
DC output power is not present.
Power supply or fan module failure.
Power supply and fan modules are opera-
tional.
AC power is OK.
No power. Output is disabled, or input power
is out of operating range.
Chapter 2. Installing the RackSwitch G8264T
33

Advertisement

Table of Contents
loading

Table of Contents