Installing or replacing a power supply module
© Copyright IBM Corp. 2012
DANGER
Multiple power cords. The product might be equipped with multiple power
cords. To remove all hazardous voltages, disconnect all power cords.
(L003)
1
2
The RackSwitch G8264T operates with either one or two active power supply
modules. Each hot-swap power supply module can be replaced by the customer
without powering off the switch or disrupting switch functions.
Each AC power supply module has a power cord for connection to an AC power
outlet.
Each power supply module has three LEDs that are visible from the rear panel. The
following table describes the LED indications:
Table 13. Power Supply Module LEDs
LED Status
OK
Green
Off
Service ( ! )
Amber
Off
~ AC Input
Green
Off
Description
DC output power is present.
DC output power is not present.
Power supply or fan module failure.
Power supply and fan modules are opera-
tional.
AC power is OK.
No power. Output is disabled, or input power
is out of operating range.
Chapter 2. Installing the RackSwitch G8264T
33