The secondary parameter specifies that the management module will be reloaded
with the secondary image.

Verifying the new software image

Enter the show version command at any CLI level to verify that all management
and interface modules are running the new software image version.

Monitoring management module redundancy

You can monitor the following aspects of management module redundancy:
v The status of the management modules (if a module is the active or standby
v The switchover history for the management modules
The following sections explain how you can monitor the management modules

Determining management module status

You can determine the status of a management module in the following ways:
v LEDs - The LEDs on the management module indicate whether a module is the
v Redundant management and module information in software - The module

Status LED

If you are located near the chassis, you can determine which management module
is currently the active module and which is the standby module by observing the
Active LED on each module. If this LED is on (green), the module is the active
module. If this LED is off, the module is the standby module.
You can also observe the Pwr LED on each module. If this LED is on (green), the
module is receiving power. If this LED is off, the module is not receiving power. (A
module without power will not function as the active or standby module.)

Software

You can use the show module CLI command to display the status of the
management modules:
The following shows an example output of the show module command.
Module Status Ports
Starting MAC
F1: SX-FISF Switch Fabric active
F2: SX-FISF Switch Fabric active
S1: SX-F424C 24-port Gig Copper OK 24
00e0.5200.0100
S2:
S3:
S4:
S5: SX-F424C 24-port Gig Copper OK 24
00e0.5200.0160
S6:
S7:
S8:
S9: SX-FI2XGMR4 2-port Management Active 2
module)
active module or the standby module, and if the module has power.
information displayed by the software indicates whether a module is the active
module or the standby module.
SX 800 Router# show module
Chapter 6. Using a redundant management module