Note: You cannot mix IPv4 and IPv6 modules together in the same chassis. A
chassis must either contain all IPv4 management modules and IPv4
interface modules or all IPv6 management modules and IPv6 interface
modules.
To install a new management module in the chassis, do the following:
1. See "Safety notices" on page xiii.
2. If your chassis does not have redundant management modules, power down the
chassis and remove the power cables from the chassis power supplies.
3. Put on the ESD wrist strap and ground yourself by inserting the plug into the
ESD connector located on the chassis front.
4. Remove the new management module from its packaging.
5. Insert the module into the chassis slot as shown in Figure 33, and slide the card
along the card guide until the ejectors on either side of the module move close
to the module front panel.
6. Push the ejectors toward the center of the module. This action will fully seat the
module in the backplane.
7. Use a #2 Phillips-head or flathead screwdriver to tighten the two screws at
either end of the management module's front panel.
Figure 33. Installing a management module in the B08S
Chapter 7. Maintaining the hardware