Saeco D.A. COMBISNACK Use And Maintenance page 14

Vending machine accessories and payment systems
Hide thumbs Also See for D.A. COMBISNACK:
Table of Contents

Advertisement

English
-
Screw the nut and fix the OR (ref. b, fig. 39) on the 2-way
solenoid valve (ref. c, fig. 39). Remove the block support
from its seat and screw the solenoid valve in the hole (fig. 45)
previously cleared from its cap (fig. 41). The solenoid valve
must be placed with fastons upwards
Reinstall the block support in their seat and tighten the screws.
-
Remove the clamp (fig. 46) that fastens the two unused cables.
-
Connect the 2 free cables to the solenoid valve taking care to
insert the red cable on the left and the white cable on the
right.
14
-
Insert the pipe clamp (ref. b, fig. 39) on pipe (ref. a, fig. 39).
Then, fasten the pipe (fig. 48) at the solenoid valve outlet and
position the pipe retaining spring.
Slide the other end of the pipe inside the assembly plate
passage hole (ref. d, fig. 48).
-
Reassemble the machine rear panel.
fig. 45
-
Fasten the pipe end with fitting to the spout (fig. 49).
fig. 46
To brew hot water alone, it is necessary to set the beverage
associated with the required key according to the following
parameters:
Parameter
Sequence
Soluble product quantity 1
H2O soluble product quantity 1
% soluble 1
sugar
-
Close the vending machine upper door.
fig. 47
d
fig. 48
fig. 49
Value
0001
0
Set the required water quantity
100
0