Siemens SIMOREG DC-MASTER Operating Instructions Manual page 49

Converter commutation protector
Table of Contents

Advertisement

12.2010
Detailed description of parameters
PNU
Description
r50047
Faults, additional information/fault addit. info
[0...31]
Description:
Display of additional information on faults that have occurred with numbers from
60000 and higher.
[0] =
fault value
[1] =
additional information on the last fault that occurred
(refer to the corresponding fault)
...
[30] = additional information on the last fault that occurred
(refer to the corresponding fault)
[31] = fault number
r50071
Rated unit supply voltage armature /
Unit Va_rated
Description:
Displays the unit rated supply voltage for the armature according to the rating
plate of the unit.
p50790
P2P interface operating mode / P2P operating mode
Description:
Sets the operating mode for the peer-to-peer interface (P2P interface).
Value:
0: No function
5: Peer-to-peer communication
6: Communication with SIMOREG CCP
Note:
Correct communication is optically displayed using an LED on the Power
Interface module C98043-A7046:
LED flashes slowly (<1 Hz): Communication with SINAMICS DCM OK
LED flashes quickly (~3 Hz): Communication error with SIMOREG CCP
p50795
P2P/CCP bus termination / P2P/CCP bus term.
Description:
Sets the bus termination for the peer-to-peer interface and the interface to the
SIMOREG CCP.
Value:
0: off
1: on
Note:
CCP: Converter Commutation Protector
P2P: Peer-to-peer interface
Siemens AG
6RX1700-0DD74
SIMOREG DC-MASTER Converter Commutation Protector
Operating Instructions
Commissioning
Value range
No. of
[dimension]
indices
Graduation
Factory
setting (FS)
-
Ind: 32
1
-
1
-
Ind: None
[Vrms]
-
-
0 to 6
Ind: None
1
FS = 0
1
0 to 1
Ind: None
1
FS = 0
1
ENGLISH
Access
level
1
1
2
2
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents