PNU
Description
U582
Response of the commutation monitoring
(2582)
This parameter can be used to define the response of the commutation -
monitoring.
1
After a commutation fault or an overcurrent condition has been
detected, this results in an immediate pulse cancellation and
Alarm message A030 is output. The pulses are enabled again
after approx. 20 ms and alarm message A030 disappears.
2
After a commutation fault or an overcurrent condition has been
detected, this results in an immediate pulse cancellation and
fault message F030 is output.
Notice:
The setting U582=1 is not permissible for a selected SIMOREG CCP
(P790=6)!
U583
Test command for the SIMOREG CCP
(2583)
This parameter can be used to issue a turn-off command to the SIMOREG
CCP for test purposes.
0
No turn-off command is issued
1
A turn-off command is issued in MI
2
A turn-off command is issued in MII
After issuing a single turn-off command to the SIMOREG CCP, this
parameter automatically sets itself back to the value 0!
Note:
If the test command is issued while operational (i.e. in operating states I and
II), then the basic converter defines the torque direction required to select
the correct test command. In the operating state, torque direction 0 (--) the
test command is issued in torque direction I.
7.1.2

SINAMICS DCM parameters

(see below for a detailed description)
r50047[0..31]
Faults, supplementary information
r50071
Rated unit supply voltage for armature
p50790
P2P interface operating mode
p50795
P2P/CCP bus termination
p50797
P2P interface telegram monitoring time
r50799[0..8]
P2P/CCP diagnostics
r51560[0..1]
CCP software version
r51569[0...15]
CCP serial number
r51570
CCP order number
r51571
CCP rated supply voltage
r51572
CCP rated current
r51574.0...12
CO/BO: CCP state
r51575
CO: CCP I2t value voltage limiting chopper 1
r51576
CO: CCP I2t value voltage limiting chopper 2
p51577
CCP chopper voltage setpoint, upper response threshold
p51578
CCP quenching capacitor pre-charging voltage setpoint
r51579.0...7
CO/BO: CCP command
p51580
Commutation monitoring, control word
p51583
CCP test turn-off command
48
ENGLISH
[from SW 2.1 and higher]
[from SW 2.2 and higher]
SIMOREG DC-MASTER Converter Commutation Protector
Value range
No. of
[dimension]
indices
Graduation
Factory
setting (FS)
Type
1 to 2
Ind: None
1
FS=2
Type: O2
0 to 2
Ind: None
1
FS = 0
Type: O2
Siemens AG
6RX1700-0DD74
Operating Instructions
12.2010
See/
change
(Access /
state)
P052 = 3
P051 = 40
online
P052 = 3
P051 = 40
online

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents