Technical Data - Siemens SIMOREG DC-MASTER Operating Instructions Manual

Converter commutation protector
Table of Contents

Advertisement

12.2010
3.2

Technical data

Order No.
6RA70...
Rated voltage
Rated current
current range that can be
covered
Rated supply voltage
Electronics power supply
Rated frequency
Power loss
Ambient temperature
Installation altitude above sea
level
Environmental class
Pollution degree
Degree of protection
Dimensions (W x H x D)
Weight (approx.)
*) Voltage derating as a function of installation altitude:
When supplying the electronics with voltages of 460 VAC phase to phase (maximum 300 VAC with respect
to ground) operation is permitted up to 4500 m. A maximum of 400 VAC phase to phase (maximum 230 V
AC with respect to ground) is permitted up to 5000 m. At higher altitudes or a higher voltage, there is no
longer "safe electrical separation" - but only basic insulation.
**) Definition, pollution degree 2:
Normally, only non-conductive pollution occurs. However, occasionally conductive pollution can be expected
for a short period of time if the electronic equipment is not operational.
Wait time, recovery time:
Each time that the line supply voltage is connected (e.g. via a line contactor):
The quenching capacitors in the unit are charged.
The wait time until the SIMOREG CCP is ready, is approx. 3 s
After one quenching operation:
The time until the SIMOREG CCP is ready again depends on the operations during the quenching
process and immediately afterwards.
The quenching capacitors in the SIMOREG CCP are again recharged to the required value,
duration approx. 10 s.
The chopper resistors, which convert the energy into heat when the armature current is reduced,
require a cooling time.
This is calculated using a software algorithm, and depending on the energy that is dissipated
during the quenching operation, is up to approx. 20 min.
Siemens AG
6RX1700-0DD74
SIMOREG DC-MASTER Converter Commutation Protector
..85-6FC00-0
..91-6FC00-0
460 V
460 V
(+15% / -20%)
(+15% / -20%)
600 A
1200 A
to 600 A
to 1200 A
2 AC 380 V (-20 %) to 460 V (+15 %); I n =1 A or
1 AC 190 V (-20 %) to 230 V (+15 %); I n =2 A
45 to 65 Hz
100 W
Operation:
0 to 55 °C
storage, transport:
-25 to +70 °C
≤ 2000 m without derating
> 2000 m with voltage derating *)
3K3 acc. to DIN IEC 60 721-3-3
2 acc. to EN50178 **)
IP00 acc. to DIN EN 60529
780 x 406 x 500 mm, dimension drawing, see Chapter 5.1
35 kg
35 kg
Operating Instructions
Description, technical data
..90-6KC00-0
..95-6FC00-0
690 V
460 V
(+10% / -20%)
(+15% / -20%)
1000 A
2000 A
to 1000 A
to 2000 A
45 kg
55 kg
ENGLISH
..95-6KC00-0
690 V
(+10% / -20%)
2000 A
to 2000 A
75 kg
17