Endress+Hauser Promass 84F Technical Information

Endress+Hauser Promass 84F Technical Information

Coriolis mass flow measuring system the universal and multivariable flowmeter for liquids and gases for custody transfe
Table of Contents

Advertisement

Technical Information

Proline Promass 84F
Coriolis Mass Flow Measuring System
The universal and multivariable flowmeter for liquids and gases
for custody transfer
Applications
The Coriolis measuring principle operates independently
of the physical fluid properties, such as viscosity and
density.
• Extremely accurate, verified measurement of liquids
(other than water) and for gases
• Fluid temperatures up to +350 °C (+660 °F)
• Process pressures up to 100 bar (1450 psi)
• Mass flow measurement
up to 2200 t/h (80840 lb/min)
Approvals for custody transfer:
• PTB, METAS, BEV, MID, NTEP, MC
Approvals for hazardous area:
• ATEX, FM, CSA, TIIS, IECEx, NEPSI
Approvals in the food industry/hygiene sector:
• 3A, FDA, EHEDG
Connection to the common process control systems:
• HART, MODBUS
Relevant safety aspects:
• Secondary containment up to 40 bar (580 psi),
Pressure Equipment Directive, AD 2000
• Purge connections or rupture disk (optional)
TI103D/06/en/02.10
71109108
Your benefits
The Promass measuring devices make it possible to
simultaneously record several process variables (mass/
density/temperature) for various process conditions
during measuring operation.
The Proline transmitter concept comprises:
• Modular device and operating concept resulting in a
higher degree of efficiency
• Diagnostic ability and data back-up for increased
process quality
The Promass sensors, tried and tested in over 100000
applications, offer:
• Best performance due to PremiumCal
• Multivariable flow measurement in compact design
• Insensitivity to vibrations thanks to balanced two-tube
measuring system
• Immune from external piping forces due to robust
design
• Easy installation without taking inlet and outlet runs
into consideration

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Promass 84F

  • Page 1: Technical Information

    Technical Information Proline Promass 84F Coriolis Mass Flow Measuring System The universal and multivariable flowmeter for liquids and gases for custody transfer Applications Your benefits The Coriolis measuring principle operates independently The Promass measuring devices make it possible to of the physical fluid properties, such as viscosity and simultaneously record several process variables (mass/ density.
  • Page 2: Table Of Contents

    Proline Promass 84F Table of contents Function and system design..... 3 Operating conditions: Process ....19 Measuring principle .
  • Page 3: Function And System Design

    Proline Promass 84F Function and system design Measuring principle The measuring principle is based on the controlled generation of Coriolis forces. These forces are always present when both translational and rotational movements are superimposed. = 2 · Δm (v · ω) = Coriolis force Δm = moving mass...
  • Page 4: Measuring System

    Proline Promass 84F Measuring system The measuring system consists of a transmitter and a sensor. Two versions are available: • Compact version: transmitter and sensor form a single mechanical unit. • Remote version: transmitter and sensor are installed separately. Transmitter Promass 84 •...
  • Page 5: Input

    Proline Promass 84F Input Measured variable • Mass flow (proportional to the phase difference between two sensors mounted on the measuring tube to register a phase shift in the oscillation) • Fluid density (proportional to resonance frequency of the measuring tube) •...
  • Page 6: Measuring Range In Custody Transfer Mode

    Proline Promass 84F Measuring range in custody The following are example data for German PTB approval (liquids other than water). transfer mode Measuring ranges for liquids in mass flow Mass flow (liquids) Q to Q Smallest measured quantity [mm] [inch]...
  • Page 7: Output

    Proline Promass 84F Output Output signal Current output, HART Active/passive selectable, galvanically isolated, time constant selectable (0.05 to 100 s), full scale value selectable, temperature coefficient: typically 0.005% o.r./°C, resolution: 0.5 μA < 700 Ω (for HART: R ≥ 250 Ω) •...
  • Page 8: Power Supply

    Proline Promass 84F Power supply Electrical connection measuring unit HART –/b –/b MODBUS RS485 a/a b/b –/c HART MODBUS RS485 – 27 A (RxD/TxD-N) + 26 B (RxD/TxD-P) – 25 – + 24 – 23 – + 22 – 21 –...
  • Page 9: Terminal Assignment

    Proline Promass 84F Terminal assignment The inputs and outputs on the communication board can be either permanently assigned (fixed) or variable (flexible), depending on the version ordered (see table). Replacements for modules which are defective or which have to be replaced can be ordered as accessories.
  • Page 10: Switching On The Power Supply In Custody Transfer Mode

    Proline Promass 84F Switching on the power If the device is started in custody transfer mode, for example also after a power outage, system error No. 271 supply in custody transfer "POWER BRK. DOWN" flashes on the local display. The fault message can be acknowledged or reset using the mode "Enter"...
  • Page 11 Proline Promass 84F Mass flow (gases) ±0.35% o.r. Density (liquids) • ±0.0005 g/cc (under reference conditions) • ±0.0005 g/cc (after field density calibration under process conditions) • ±0.001 g/cc (after special density calibration) • ±0.01 g/cc (over the entire measuring range of the sensor)
  • Page 12: Repeatability

    Proline Promass 84F Example for max. measured error ±1.0 ±0.5 ±0.2 18 t/h a0004604 Max. measured error in % o.r. (example: Promass 84F / DN 25) Flow values (example) Design fundamentals → ä 13 Turn down Flow Max. measured error [kg/h] [lb/min] [% o.r.]...
  • Page 13: Influence Of Medium Temperature

    Proline Promass 84F Influence of medium When there is a difference between the temperature for zero point adjustment and the process temperature, temperature the typical measured error of the Promass sensor is ±0.0002% of the full scale value / °C (±0.0001% of the full scale value / °F).
  • Page 14: Operating Conditions: Installation

    Proline Promass 84F Operating conditions: Installation Installation instructions Note the following points: • No special measures such as supports are necessary. External forces are absorbed by the construction of the instrument, for example the secondary containment. • The high oscillation frequency of the measuring tubes ensures that the correct operation of the measuring system is not influenced by pipe vibrations.
  • Page 15 Proline Promass 84F ∅ Orifice plate, pipe restriction [mm] [inch] inch 3/8" 0.24 ½" 0.40 1" 0.55 1½" 0.87 2" 1.10 3" 2.00 4" 2.60 6" 3.54 10" 5.91 Orientation Make sure that the direction of the arrow on the nameplate of the sensor matches the direction of flow (direction in which the fluid flows through the pipe).
  • Page 16 – Relative magnetic permeability μ – Plate thickness d ≥ 0.35 mm (d ≥ 0.014") • Information on permissible temperature ranges → ä 19 Special heating jackets which can be ordered as accessories from Endress+Hauser are available for the sensors. Endress+Hauser...
  • Page 17: Inlet And Outlet Runs

    Proline Promass 84F Thermal insulation Some fluids require suitable measures to avoid loss of heat at the sensor. A wide range of materials can be used to provide the required thermal insulation. a0004614-ae High-temperature version: maximum insulation thickness of 60 mm (2.4") in the area of the electronics/neck If the Promass F high-temperature version is installed horizontally (with transmitter head pointing upwards), an insulation thickness of min.
  • Page 18: Operating Conditions: Environment

    Proline Promass 84F Operating conditions: Environment Ambient temperature range Sensor, transmitter • Standard: –20 to +60 °C (–4 to +140 °F) • Optional: –40 to +60 °C (–40 to +140 °F) Note! • Install the device at a shady location. Avoid direct sunlight, particularly in warm climatic regions.
  • Page 19: Operating Conditions: Process

    Proline Promass 84F Operating conditions: Process Medium temperature range Sensor • –50 to +200 °C (–58 to +392 °F) • High-temperature version: –50 to +350 °C (–58 to +660 °F) Medium pressure range Flanges (nominal pressure) • Standard: – according to DIN PN 16 to 100 –...
  • Page 20: Pressure Loss

    Proline Promass 84F Pressure loss Pressure loss depends on the properties of the fluid and on its flow. The following formulas can be used to approximately calculate the pressure loss: 2 · Re = Reynolds number · d · ·...
  • Page 21 Proline Promass 84F Pressure loss (US units) Pressure loss is dependent on fluid properties nominal diameter. Consult Endress+Hauser for Applicator PC software to determine pressure loss in US units. All important instrument data is contained in the Applicator software programm in order to optimize the design of measuring system. The software is used for following calculations: •...
  • Page 22: Custody Transfer Measurement

    Proline Promass 84F Custody transfer measurement Promass 84 is a flowmeter suitable for custody transfer measurement for liquids (other than water) and gases. Custody transfer variables • Mass flow • Volume flow • Density Suitability for custody transfer, Promass 84 flowmeters are usually verified on site using reference measurements. Only once it has been...
  • Page 23: Stamp Points

    Proline Promass 84F Stamp points a0003467 Examples of how to seal the various device versions. Disabling custody transfer mode A detailed description of the "disabling custody transfer mode" process is provided in the Operating Instructions supplied with the device. Endress+Hauser...
  • Page 24: Mechanical Construction

    Proline Promass 84F Mechanical construction Design/dimensions Abmessungen: → ä 25 Transmitter compact version, powder coated die-cast aluminium field housing → ä 26 Transmitter compact version, stainless steel field housing → ä 26 Transmitter and remote field housing (II2G/zone 1) → ä 27 Transmitter wall-mount housing (non hazardous area and II3G/zone 2) →...
  • Page 25: Transmitter Compact Version, Powder Coated Die-Cast Aluminium Field Housing

    Proline Promass 84F Transmitter compact version, powder coated die-cast aluminium field housing a0003165 Dimensions in SI units * Blind version (without local display) dependent on respective process connection All dimensions in [mm] Dimensions in US units 3/8" 8.94 8.15 7.68 6.61...
  • Page 26: Transmitter Compact Version, Stainless Steel Field Housing

    Proline Promass 84F Transmitter compact version, stainless steel field housing a0002245 Dimensions in SI and US units [mm] [inch] [mm] [inch] [mm] [inch] 8.86 6.02 6.61 Transmitter and remote field housing (II2G/zone 1) Nicht-eigensichere Stromkreise durch IP40-Abdeckung geschützt Non-intrinsically safe...
  • Page 27: Transmitter Wall-Mount Housing (Non Hazardous Area And Ii3G/Zone 2)

    Proline Promass 84F Transmitter wall-mount housing (non hazardous area and II3G/zone 2) a0001150 Dimensions in SI units 90.5 159.5 >50 81.5 11.5 8 × M5 All dimensions in [mm] Dimensions in US units 8.46 9.84 3.56 6.27 5.31 3.54 1.77 >1.97...
  • Page 28: Connection Housing Remote Version

    Proline Promass 84F Connection housing remote version a0002516 Dimensions in SI units 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 All dimensions in [mm] Dimensions in US units 3/8" 4.67 5.41...
  • Page 29: Connection Housing Remote Version, Connection Housing With An Extended Neck

    Proline Promass 84F Connection housing remote version, connection housing with an extended neck Note! Use this version in case of insulation or application of heating jacket. a0002517 Dimensions in SI and US units [mm] [inch] [mm] [inch] [mm] [inch] [mm]...
  • Page 30: High-Temperature Version (Compact)

    Proline Promass 84F High-temperature version (compact) a0002518 Dimensions in SI units All dimensions in [mm] Dimensions in US units 1" 7.36 6.61 3.94 13.78 17.72 2" 7.36 6.61 5.55 14.37 19.92 3" 7.36 6.61 7.87 15.16 23.03 All dimensions in [inch]...
  • Page 31: High-Temperature Version (Remote)

    Proline Promass 84F High-temperature version (remote) a0002519 Dimensions in SI units All dimensions in [mm] Dimensions in US units 1" 5.08 11.50 4.13 15.63 2" 5.08 12.09 5.55 17.64 3" 5.08 12.87 7.87 20.75 All dimensions in [inch] Endress+Hauser...
  • Page 32: Process Connections In Si Units

    Proline Promass 84F Process connections in SI units Flange connections EN (DIN), ASME B16.5, JIS +1.5 (+0.06)* mm (inch) –2.0 (–0.08)* *DN 150…250: ±3.5 (6" …10": ±0.14) a0002501-ae Flange connections EN (DIN) Flange according to EN 1092-1 (DIN 2501 / DIN 2512N ) / PN 16: 1.4404/316L...
  • Page 33 Proline Promass 84F Flange according to EN 1092-1 (DIN 2501) / PN 40 (with DN 25-Flanges): 1.4404/316L Surface roughness (flange): EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 μm 4 × Ø14 28.5 5.35 4 × Ø14 28.5...
  • Page 34 Proline Promass 84F Flange EN 1092-1 (DIN 2501 / DIN 2512N ) / PN 100: 1.4404/316L, Alloy C-22 Surface roughness (flange): EN 1092-1 Form B2 (DIN 2526 Form E), Ra 0.8 to 3.2 μm 4 × Ø14 17.3 5.35 4 × Ø14 17.3...
  • Page 35: Flange Connections Asme B16.5

    Proline Promass 84F Flange connections ASME B16.5 Flange according to ASME B16.5 / Cl 150: 1.4404/316L, Alloy C-22 Surface roughness (flange): Ra 3.2 to 6.3 μm 88.9 370.0 4 × Ø15.7 11.2 60.5 15.7 5.35 88.9 404.0 4 × Ø15.7 11.2...
  • Page 36 Proline Promass 84F Flange according to ASME B16.5 / Cl 600: 1.4404/316L, Alloy C-22 Surface roughness (flange): Ra 3.2 to 6.3 μm 95.3 400.0 4 × Ø15.7 20.6 66.5 13.9 5.35 95.3 420.0 4 × Ø15.7 20.6 66.5 13.9 8.30 124.0...
  • Page 37: Flange Connections Jis B2220 → Ä

    Proline Promass 84F Flange connections JIS B2220 Flange JIS B2220 / 10K: 1.4404/316L, Alloy C-22 Surface roughness (flange): Ra 1.6 to 3.2 μm 4 × Ø19 26.00 8 × Ø19 40.50 1128 8 × Ø19 51.20 1354 8 × Ø23 68.90...
  • Page 38 Proline Promass 84F Flange JIS B2220 / 63K: 1.4404/316L, Alloy C-22 Surface roughness (flange): Ra 1.6 to 3.2 μm 4 × Ø19 5.35 4 × Ø19 8.30 4 × Ø23 12.00 4 × Ø25 17.60 8 × Ø23 26.00 8 × Ø25 40.50...
  • Page 39: Tri-Clamp → Ä

    Proline Promass 84F Tri-Clamp +1.5 (+0.06) mm (inch) –2.0 (–0.08) a0002515-ae Tri-Clamp: 1.4404/316L Clamp 1" 50.4 22.1 5.35 1" 50.4 22.1 8.30 1" 50.4 22.1 12.00 1½" 50.4 34.8 17.60 2" 63.9 47.5 26.00 3" 90.9 72.9 40.50 4" 118.9 1128 97.4...
  • Page 40: Din 11851 (Threaded Hygienic Connection)

    Proline Promass 84F DIN 11851 (threaded hygienic connection) +1.5 (+0.06) mm (inch) –2.0 (–0.08) a0002520-ae Threaded hygienic connection DIN 11851: 1.4404/316L Rd 34 × 1/8" 5.35 Rd 34 × 1/8" 8.30 Rd 52 × 1/6" 12.00 Rd 65 × 1/6"...
  • Page 41: Din 11864-1 Form A (Threaded Hygienic Connection) → Ä

    Proline Promass 84F DIN 11864-1 Form A (threaded hygienic connection) +1.5 (+0.06) mm (inch) –2.0 (–0.08) a0002521-ae Threaded hygienic connection DIN 11864-1 Form A: 1.4404/316L Rd 28 × 1/8" 5.35 Rd 34 × 1/8" 8.30 Rd 52 × 1/6" 12.00 Rd 65 ×...
  • Page 42: Din 11864-2 Form A (Flat Flange With Groove) → Ä

    Proline Promass 84F DIN 11864-2 Form A (flat flange with groove) +1.5 (+0.06) –2.0 (–0.08) mm (inch) a0002522-ae Detail A: The flange has the smaller groove for the O-ring on the sensor side. When mounting the sensor the corresponding flange must have accordingly a larger groove.
  • Page 43: Iso 2853 (Threaded Hygienic Connection) → Ä

    Proline Promass 84F ISO 2853 (threaded hygienic connection) +1.5 (+0.06) mm (inch) –2.0 (–0.08) a0002523-ae Threaded hygienic connection ISO 2853: 1.4404/316L 37.13 22.6 5.35 37.13 22.6 8.30 37.13 22.6 12.00 52.68 35.6 17.60 64.16 48.6 26.00 91.19 72.9 40.50 118.21 1128 97.6...
  • Page 44: Sms 1145 (Threaded Hygienic Connection)

    Proline Promass 84F SMS 1145 (threaded hygienic connection) +1.5 (+0.06) mm (inch) –2.0 (–0.08) a0002524-ae Threaded hygienic connections SMS 1145: 1.4404/316L Rd 40 x 1/6" 22.6 5.35 Rd 40 x 1/6" 22.6 8.30 Rd 40 x 1/6" 22.6 12.00 Rd 60 x 1/6"...
  • Page 45: Vco Connections → Ä

    Proline Promass 84F VCO connections +1.5 (+0.06) mm (inch) –2.0 (–0.08) a0004552-ae 8-VCO-4 (½"): 1.4404/316L AF 1" 10.2 5.35 All dimensions in [mm] 12-VCO-4 (¾"): 1.4404/316L AF 1½" 15,7 8,30 All dimensions in [mm] Endress+Hauser...
  • Page 46 Proline Promass 84F Process connections in US units Flange connections ASME B16.5 +1.5 (+0.06)* mm (inch) –2.0 (–0.08)* *DN 150…250: ±3.5 (6" …10": ±0.14) a0002501-ae Flange according to ASME B16.5 / Cl 150: 1.4404/316L, Alloy C-22 Surface roughness (flange): Ra 3.2 to 6.3 μm 3/8"...
  • Page 47 Proline Promass 84F Flange according to ASME B16.5 / Cl 600: 1.4404/316L, Alloy C-22 Surface roughness (flange): Ra 3.2 to 6.3 μm 3/8" 3.75 15.75 4 × Ø0.62 0.81 2.62 0.55 0.21 ½" 3.75 16.54 4 × Ø0.62 0.81 2.62 0.55...
  • Page 48 Proline Promass 84F Tri-Clamp +1.5 (+0.06) mm (inch) –2.0 (–0.08) a0002515-ae Tri-Clamp: 1.4404/316L Clamp 3/8" 1" 1.98 14.4 0.87 0.21 ½" 1" 1.98 15.7 0.87 0.33 1" 1" 1.98 17.1 0.87 0.47 1½" 1½" 1.98 22.0 1.37 0.69 2" 2"...
  • Page 49 Proline Promass 84F SMS 1145 (Threaded hygienic connection) +1.5 (+0.06) mm (inch) –2.0 (–0.08) a0002524-ae Threaded hygienic connection SMS 1145: 1.4404/316L 3/8" Rd 40 × 1/6" 14.68 0.904 0.214 ½" Rd 40 × 1/6" 15.92 0.904 0.332 1" Rd 40 × 1/6"...
  • Page 50 Proline Promass 84F VCO connections +1.5 (+0.06) mm (inch) –2.0 (–0.08) a0004552-ae 8-VCO-4 (½"): 1.4404/316L 3/8" AF 1" 15.35 0.40 0.21 All dimensions in [inch] 12-VCO-4 (¾"): 1.4404/316L ½" AF 1½" 16.93 0.62 0.33 All dimensions in [inch] Endress+Hauser...
  • Page 51 Proline Promass 84F Purge connections / secondary containment monitoring " Caution! • The secondary containment is filled with dry nitrogen (N ). Do not open the purge connections unless the containment can be filled immediately with a dry inert gas. Use only low gauge pressure to purge.
  • Page 52 Proline Promass 84F Rupture disk Sensor housings with integrated rupture disks are optionally available. Warning! • Make sure that the function and operation of the rupture disk is not impeded through the installation. Triggering overpressure in the housing as stated on the indication label. Take adequate precautions to ensure that no damage occurs, and risk to human life is ruled out, if the rupture disk is triggered.
  • Page 53 Proline Promass 84F RUPTURE DISK 12,5 BAR +/-10%@80°C A0009733 DN 250 (10") Indication label for the rupture disk ½" NPT internal screw thread with 1" width across flat Transport protection [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] 10" ca. 42 ca.
  • Page 54: Weight

    Proline Promass 84F Weight • Compact version: see table below • Remote version – Sensor: see table below – Wall-mount housing: 5 kg (11 lbs) Weight information in SI units DN [mm] Compact version High-temperature compact version – – 14.7 –...
  • Page 55: Material

    Proline Promass 84F Material Transmitter housing Compact version • Compact version: powder coated die-cast aluminium • Stainless steel housing: stainless steel 1.4301/ASTM 304 • Window material: glass or polycarbonate Remote version • Remote field housing: powder coated die-cast aluminium • Wall-mount housing: powder coated die-cast aluminium •...
  • Page 56: Material Load Diagram

    Proline Promass 84F Material load diagram Warning! The following material load curves refer to the entire sensor and not just the process connection. Flange connection according to EN 1092-1 (DIN 2501) Flange material: 1.4404/316L, Alloy C-22 [psi] [bar] 1500 1400...
  • Page 57 Proline Promass 84F Flange connection to JIS B2220 Flange material: 1.4404/316L, Alloy C-22 [psi] [bar] 1000 -60 -40 -20 80 100 120 140 180 200 220 240 260 280 300 320 340 [°C] [°F] 120 160 200 240 280 320 360 400...
  • Page 58 Proline Promass 84F Tri-Clamp process connection The Clamp connections are suited up to a maximum pressure of 16 bar (232 psi). Please observe the operating limits of the clamp and seal used as they could be under 16 bar (232 psi). The clamp and the seal are not included in the scope of supply.
  • Page 59: Process Connections

    Proline Promass 84F VCO process connection Connection material: 1.4404/316L [psi] [bar] 1500 1400 PN 100 1300 1200 1100 1000 [°C] -60 -40 -20 80 100 120 140 180 200 [°F] 120 160 240 280 a0004553-ae Process connections • Flanges according to EN 1092-1 (DIN 2501), according to ASME B16.5, JIS B2220, VCO connections •...
  • Page 60: Certificates And Approvals

    CE mark The measuring system is in conformity with the statutory requirements of the EC Directives. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. C-tick mark The measuring system meets the EMC requirements of the Australian Communication and Media Authority (ACMA).
  • Page 61: Approval For Custody Transfer

    Proline Promass 84F Approval for custody transfer Promass 84 is a flowmeter suitable for custody transfer measurement for liquids (other than water) and for fuel gases under high pressure (> 100 bar (> 1450 psi)). The requirements of the following test centres are taken into consideration: •...
  • Page 62: Ordering Information

    The Endress +Hauser service organization can provide detailed ordering information and information on the order codes upon request. Accessories Various accessories, which can be ordered separately from Endress+Hauser, are available for the transmitter and the sensor. Documentation • Flow measuring technology (FA005D) •...
  • Page 63 Proline Promass 84F Endress+Hauser...
  • Page 64 Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel. +41 61 715 81 00 Fax +41 61 715 25 00 www.endress.com info@ii.endress.com TI103D/06/en/02.10 71109108 FM+SGML6.0 ProMoD...

Table of Contents