Endress+Hauser Proline Promass 84F Technical Information
Endress+Hauser Proline Promass 84F Technical Information

Endress+Hauser Proline Promass 84F Technical Information

Coriolis mass flow measuring system
Hide thumbs Also See for Proline Promass 84F:
Table of Contents

Advertisement

Technical Information

Proline Promass 84F, 84M
Coriolis Mass Flow Measuring System
The universal and multivariable flowmeter for liquids and gases
for custody transfer
Applications
The Coriolis measuring principle operates independently
of the physical fluid properties, such as viscosity and
density.
• Extremely accurate, verified measurement of
liquids (other than water) and for gases under
high pressure (>100 bar)
• Fluid temperatures up to +350 °C
• Process pressures up to 350 bar
• Mass flow measurement up to 2200 t/h
Approvals for custody transfer:
• PTB, NMi, METAS, BEV, NTEP, MC
Approvals for hazardous area:
• ATEX, FM, CSA, TIIS, IECEx, NEPSI
Approvals in the food industry/hygiene sector:
• 3A, FDA, EHEDG
Connection to process control system:
• HART, MODBUS
Relevant safety aspects:
• Secondary containment (up to 100 bar), Pressure
Equipment Directive, AD 2000
• Purge connections or rupture disk (optional)
TI067D/06/en/07.08
71076893
Your benefits
The Promass measuring devices make it possible to
simultaneously record several process variables (mass/
density/temperature) for various process conditions
during measuring operation.
The Proline transmitter concept comprises:
• Modular device and operating concept resulting in a
higher degree of efficiency
• Diagnostic ability and data back-up for increased
process quality
The Promass sensors, tried and tested in over 100000
applications, offer:
• Best performance due to PremiumCal
• Multivariable flow measurement in compact design
• Insensitivity to vibrations thanks to balanced two-tube
measuring system
• Immune from external piping forces due to robust
design
• Easy installation without taking inlet and outlet runs
into consideration

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Proline Promass 84F

  • Page 1: Technical Information

    Technical Information Proline Promass 84F, 84M Coriolis Mass Flow Measuring System The universal and multivariable flowmeter for liquids and gases for custody transfer Applications Your benefits The Coriolis measuring principle operates independently The Promass measuring devices make it possible to...
  • Page 2: Table Of Contents

    Proline Promass 84F, 84M Table of contents Function and system design..... 3 Operating conditions: Process ....21 Measuring principle .
  • Page 3: Function And System Design

    Proline Promass 84F, 84M Function and system design Measuring principle The measuring principle is based on the controlled generation of Coriolis forces. These forces are always present when both translational and rotational movements are superimposed. = 2 · Δm (v · ω) = Coriolis force Δm = moving mass...
  • Page 4: Measuring System

    Proline Promass 84F, 84M Measuring system The measuring system consists of a transmitter and a sensor. Two versions are available: • Compact version: transmitter and sensor form a single mechanical unit. • Remote version: transmitter and sensor are installed separately.
  • Page 5: Input

    Proline Promass 84F, 84M Input Measured variable • Mass flow (proportional to the phase difference between two sensors mounted on the measuring tube to register a phase shift in the oscillation) • Fluid density (proportional to resonance frequency of the measuring tube) •...
  • Page 6: Measuring Range In Custody Transfer Mode

    Proline Promass 84F, 84M Measuring range in custody The following are example data for German PTB approval (liquids other than water). transfer mode Measuring ranges for liquids in mass flow for Promass F Mass flow (liquids) Q to Q Smallest measured quantity...
  • Page 7: Operable Flow Range

    Proline Promass 84F, 84M Measuring ranges for high pressure fuel gases CNG for Promass M Mass flow (liquids) Q to Q Smallest measured quantity [mm] [kg/min] [kg] 0.1 to 10 0.3 to 40 1.0 to 100 Max. Pressure = 250 bar resp. 350 bar for high pressure version Note! For information about the other approvals →...
  • Page 8: Signal On Alarm

    Proline Promass 84F, 84M MODBUS RS485 • MODBUS device type: slave • Address range: 1 to 247 • Functions codes supported: 03, 04, 06, 08, 16, 23 • Broadcast: supported with the function codes 06, 16, 23 • Physical interface: RS485 in accordance with standard EIA/TIA-485 •...
  • Page 9: Power Supply

    Proline Promass 84F, 84M Power supply Electrical connection measuring unit HART –/b –/b MODBUS RS485 a/a b/b –/c HART MODBUS RS485 – 27 A (RxD/TxD-N) + 26 B (RxD/TxD-P) – 25 – + 24 – 23 – + 22 – 21 –...
  • Page 10: Terminal Assignment

    Proline Promass 84F, 84M Terminal assignment Replacements for modules which are defective or which have to be replaced can be ordered as accessories. Terminal No. (inputs/outputs) Order variant 20 (+) / 21 (–) 22 (+) / 23 (–) 24 (+) / 25 (–) 26 (+) / 27 (–)
  • Page 11: Supply Voltage

    Proline Promass 84F, 84M Supply voltage 85 to 260 V AC, 45 to 65 Hz 20 to 55 V AC, 45 to 65 Hz 16 to 62 V DC Switching on the power If the device is started in custody transfer mode, for example also after a power outage, system error No. 271 supply in custody transfer "POWER BRK.
  • Page 12: Performance Characteristics

    Proline Promass 84F, 84M Performance characteristics Note! The accuracy solely refers to the measuring device suitable for custody transfer measurement and not to the measuring system. Reference operating Error limits following ISO/DIS 11631: conditions • 20 to 30 °C; 2 to 4 bar •...
  • Page 13: Repeatability

    Proline Promass 84F, 84M Sample calculation ±1.0 ±0.5 ±0.2 18 t/h a0004604 Maximum measured error in % of reading (example: Promass 84F / DN 25) Calculation example (mass flow, liquid): Given: Promass 84F / DN 25, measured value flow = 8000 kg/h Max.
  • Page 14: Influence Of Medium Temperature

    Proline Promass 84F, 84M Density measurement (liquid) 1 g/cc = 1 kg/l • Promass F: ±0.00025 g/cc • Promass M: ±0.0005 g/cc Temperature measurement ±0.25 °C ±0.0025 · T; (T = fluid temperature in °C) Influence of medium When there is a difference between the temperature for zero point adjustment and the process temperature, temperature the typical measured error of the Promass sensor is ±0.0002% of the full scale value / °C.
  • Page 15: Operating Conditions: Installation

    Proline Promass 84F, 84M Operating conditions: Installation Installation instructions Note the following points: • No special measures such as supports are necessary. External forces are absorbed by the construction of the instrument, for example the secondary containment. • The high oscillation frequency of the measuring tubes ensures that the correct operation of the measuring system is not influenced by pipe vibrations.
  • Page 16 Proline Promass 84F, 84M ∅ Orifice plate, pipe restriction [mm] 1) only Promass F Orientation Make sure that the direction of the arrow on the nameplate of the sensor matches the direction of flow (direction in which the fluid flows through the pipe).
  • Page 17 ≥ 300 – Relative magnetic permeability μ – Plate thickness d ≥ 0.35 mm • Information on permissible temperature ranges → Page 21 Special heating jackets which can be ordered as accessories from Endress+Hauser are available for the sensors. Endress+Hauser...
  • Page 18 Proline Promass 84F, 84M Thermal insulation Some fluids require suitable measures to avoid loss of heat at the sensor. A wide range of materials can be used to provide the required thermal insulation. a0004614-en In the case of the Promass F high-temperature version, a maximum insulation thickness of 60 mm must be observed in the area of the electronics/neck.
  • Page 19: Inlet And Outlet Runs

    Proline Promass 84F, 84M Inlet and outlet runs There are no installation requirements regarding inlet and outlet runs. Length of connecting cable max. 20 m remote version System pressure It is important to ensure that cavitation does not occur, because it would influence the oscillation of the measuring tube.
  • Page 20: Operating Conditions: Environment

    Proline Promass 84F, 84M Operating conditions: Environment Ambient temperature range Sensor and transmitter Standard: –20 to +60 °C Optional: –40 to +60 °C Note! • Install the device at a shady location. Avoid direct sunlight, particularly in warm climatic regions.
  • Page 21: Operating Conditions: Process

    Proline Promass 84F, 84M Operating conditions: Process Medium temperature range Sensor • Promass F: –50 to +200 °C • Promass F (High temperature version): –50 to +350 °C • Promass M: –50 to +150 °C Seals • Promass F: No internal seals •...
  • Page 22: Limiting Flow

    Proline Promass 84F, 84M See "Measuring range" section. → Page 68 ff. Limiting flow Select nominal diameter by optimising between required flow range and permissible pressure loss. An overview of max. possible full scale values can be found in the "Measuring range" Section.
  • Page 23 Proline Promass 84F, 84M [mbar] 10000 DN 25 DN 8 DN 15 DN 50 DN 40 DN 100 1000 DN 80 DN 150 DN 250 0.01 0.001 1000 [t/h] a0001396 Pressure loss diagram for water Pressure loss coefficient for Promass M d[m] –3...
  • Page 24: Pressure Loss In Us Units

    Proline Promass 84F, 84M Pressure loss in US units Pressure loss ist dependent on fluid properties nominal diameter. Consult Endress+Hauser for Applicator PC software to determine pressure loss in US units. All important instrument data is contained in the Applicator software programm in order to optimize the design of measuring system.
  • Page 25: Custody Transfer Measurement

    Proline Promass 84F, 84M Custody transfer measurement Promass 84 is a flowmeter suitable for custody transfer measurement for liquids (other than water) and gases. Custody transfer variables • Mass • Volume • Density Suitability for custody transfer, Promass 84 flowmeters are usually verified on site using reference measurements. Only once it has been...
  • Page 26: Stamp Points

    Proline Promass 84F, 84M Stamp points a0003467 Examples of how to seal the various device versions. Disabling custody transfer mode A detailed description of the "disabling custody transfer mode" process is provided in the Operating Instructions supplied with the device.
  • Page 27: Mechanical Construction

    Proline Promass 84F, 84M Mechanical construction Design/dimensions Dimensions: in metric units → Page 28 Transmitter compact version, powder coated die-cast aluminium field housing → Page 28 Transmitter compact version, powder coated die-cast aluminium field housing → Page 29 Transmitter compact version, stainless steel field housing →...
  • Page 28 Proline Promass 84F, 84M Transmitter compact version, powder coated die-cast aluminium field housing a0003165 Promass F a0003165 Promass M All dimensions in [mm] * Blind version (without display) Promass F Promass M All dimensions in [mm] depends on the process connection →...
  • Page 29 Proline Promass 84F, 84M Transmitter compact version, stainless steel field housing a0002245 All dimensions in [mm] Transmitter and remote field housing (II2G/zone 1) Nicht-eigensichere Stromkreise durch IP40-Abdeckung geschützt Non-intrinsically safe circuits Ip40 protected Boucles de courant sans sécurité intrinsèque protégées par Ip40...
  • Page 30 Proline Promass 84F, 84M Transmitter wall-mount housing (non hazardous area and II3G/zone 2) a0001150 90.5 159.5 > 50 81.5 11.5 8 × M5 All dimensions in [mm] Endress+Hauser...
  • Page 31 Proline Promass 84F, 84M Connetion housing remote version a0002516 Promass F Promass M 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 118.5 137.5 All dimensions in [mm] 118.5...
  • Page 32 Proline Promass 84F, 84M Promass F: Flange connections EN (DIN) +1.5* –2.0* *DN 150…250: ±3.5 a0002501-en Flange according to EN 1092-1 (DIN 2501 / DIN 2512N ) / PN 16: 1.4404/316L Surface roughness (flange): EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 μm 1128 8 ×...
  • Page 33 Proline Promass 84F, 84M Flange according to EN 1092-1 (DIN 2501) / PN 40 (with DN 25-Flanges): 1.4404/316L Surface roughness (flange): EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 μm 4 × Ø 14 28.5 5.35 4 ×...
  • Page 34 Proline Promass 84F, 84M Promass F: Flange connections ASME B16.5 +1.5* –2.0* *DN 150…250: ±3.5 a0002501-en Flange according to ASME B16.5 / Cl 150: 1.4404/316L, Alloy C-22 Surface roughness (flange): Ra 3.2 to 6.3 μm 88.9 4 × Ø 15.7 11.2...
  • Page 35 Proline Promass 84F, 84M Flange according to ASME B16.5 / Cl 300: 1.4404/316L, Alloy C-22 Surface roughness (flange): Ra 3.2 to 6.3 μm 95.2 4 × Ø 15.7 14.2 66.5 15.7 5.35 95.2 4 × Ø 15.7 14.2 66.5 15.7 8.30...
  • Page 36 Proline Promass 84F, 84M Flange according to ASME B16.5 extension - reduction / Cl 600: 1.4404/316L Only for nominal diameter DN 250 /10" (on request) Surface roughness (flange): Ra 3.2 to 6.3 μm 355.6 1980 12 × Ø 28.4 54.2 292.1...
  • Page 37 Proline Promass 84F, 84M Flange JIS B2220 / 20K: 1.4404/316L, Alloy C-22 Surface roughness (flange): Ra 1.6 to 3.2 μm 4 × Ø 15 5.35 4 × Ø 15 8.30 4 × Ø 19 12.00 4 × Ø 19 17.60 8 ×...
  • Page 38 Proline Promass 84F, 84M Flange JIS B2220 / 63K: 1.4404/316L, Alloy C-22 Surface roughness (flange): Ra 1.6 to 3.2 μm 4 × Ø 19 5.35 4 × Ø 19 8.30 4 × Ø 23 12.00 4 × Ø 25 17.60 8 ×...
  • Page 39 Proline Promass 84F, 84M Promass F: Tri-Clamp +1.5 –2.0 a0002515-en Tri-Clamp: 1.4404/316L Clamp 1" 50.4 22.1 5.35 1" 50.4 22.1 8.30 1" 50.4 22.1 12.00 1 ½" 50.4 34.8 17.60 2" 63.9 47.5 26.00 3" 90.9 72.9 40.50 4" 118.9 1128 97.4...
  • Page 40 Proline Promass 84F, 84M Promass F: DIN 11851 connections (threaded hygienic connection) +1.5 –2.0 a0002520-en Threaded hygienic connection DIN 11851: 1.4404/316L Rd 34 × 1/8" 5.35 Rd 34 × 1/8" 8.30 Rd 52 × 1/6" 12.00 Rd 65 × 1/6"...
  • Page 41 Proline Promass 84F, 84M Promass F: DIN 11864-2 Form A (flat flange with groove) +1.5 –2.0 a0002522-en DIN 11864-2 Form A (flat fange with groove): 1.4404/316L 4 × Ø 9 5.35 4 × Ø 9 8.30 4 × Ø 9 12.00...
  • Page 42 Proline Promass 84F, 84M Promass F: SMS 1145 (threaded hygienic connection) +1.5 –2.0 a0002524-en threaded hygienic connection SMS 1145: 1.4404/316L Rd 40 x 1/6" 22.6 5.35 Rd 40 x 1/6" 22.6 8.30 Rd 40 x 1/6" 22.6 12.00 Rd 60 x 1/6"...
  • Page 43 Proline Promass 84F, 84M Flange according to EN 1092-1 (DIN 2501 / DIN 2512N ) / PN 40: 1.4404/316L, Titan Surface roughness (flange): EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 μm 4 × Ø 14 17.3...
  • Page 44 Proline Promass 84F, 84M Promass M: Flange connections ASME B16.5 +1.5 –2.0 a0002525-en Flange according to ASME B16.5 / Cl 150: 1.4404/316L, Titan Surface roughness (flange): Ra 3.2 to 6.3 μm 88.9 4 × Ø 15.7 11.2 60.5 15.7 5.53 88.9...
  • Page 45 Proline Promass 84F, 84M Flange according to ASME B16.5 / Cl 600: 1.4404/316L, Titan Surface roughness (flange): Ra 3.2 to 6.3 μm 95.3 4 × Ø 15.7 20.6 66.5 13.8 5.53 95.3 4 × Ø 15.7 20.6 66.5 13.8 8.55 124.0...
  • Page 46 Proline Promass 84F, 84M Flange JIS B2220 / 20K: 1.4404/316L, Titan Surface roughness (flange): Ra 3.2 to 6.3 μm 4 × Ø 15 5.53 4 × Ø 15 8.55 4 × Ø 19 11.38 4 × Ø 19 17.07 4 × Ø 19 25.60...
  • Page 47 Proline Promass 84F, 84M Promass M: Tri-Clamp +1.5 –2.0 a0002526-en Tri-Clamp: 1.4404/316L Clamp 1" 50.4 22.1 5.53 1" 50.4 22.1 8.55 1" 50.4 22.1 11.38 1 ½" 50.4 34.8 17.07 2" 63.9 47.5 25.60 3" 90.9 72.9 38.46 All dimensions in [mm]; Further dimensions → Page 28 ff.
  • Page 48 Proline Promass 84F, 84M Promass M: DIN 11851 (threaded hygienic connection) +1.5 –2.0 a0002527-en Threaded hygienic connection DIN 11851: 1.4404/316L Rd 34 × 1/8" 5.53 Rd 34 × 1/8" 8.55 Rd 52 × 1/6" 11.38 Rd 65 × 1/6" 17.07 Rd 78 ×...
  • Page 49 Proline Promass 84F, 84M Promass M: DIN 11864-2 Form A (flat flange with groove) +1.5 –2.0 a0002529-en DIN 11864-2 Form A (flat flange with groove): 1.4404/316L 4 × Ø 9 5.53 4 × Ø 9 8.55 4 × Ø 9 11.38...
  • Page 50 Proline Promass 84F, 84M Promass M: SMS 1145 (threaded hygienic connection) +1.5 –2.0 a0002531-en Threaded hygienic connection SMS 1145: 1.4404/316L Rd 40 × 1/6" 22.5 5.53 Rd 40 × 1/6" 22.5 8.55 Rd 40 × 1/6" 22.5 11.38 Rd 60 × 1/6"...
  • Page 51 Proline Promass 84F, 84M Promass M (high pressure): ½"-SWAGELOK +1.5 –2.0 a0002533-en ½"-SWAGELOK: 1.4404/316L 7/8" 366.4 10.2 4.93 7/8" 396.4 10.2 7.75 7/8" 440.4 10.2 10.20 All dimensions in [mm]; Further dimensions → Page 28 ff. Promass M (high pressure): Connector with internal thread 7/8-14UNF +1.5...
  • Page 52 Proline Promass 84F, 84M Promass M: without process connections +1.5 –2.0 A DN 8 - 25 A DN 40 - 50 A DN 80 a0002535-en max. min. 6 × M 8 6 × M 8 6 × M 8 6 × M 8 6 ×...
  • Page 53 Proline Promass 84F, 84M Purge connections / secondary containment monitoring " Caution! • The secondary containment is filled with dry nitrogen (N ). Do not open the purge connections unless the containment can be filled immediately with a dry inert gas. Use only low gauge pressure to purge.
  • Page 54 Proline Promass 84F, 84M Promass M: a0002536 44.0 46.5 50.0 ½"-NPT 59.0 67.5 81.5 All dimensions in [mm] Rupture disk Sensor housings with integrated rupture disks are optionally available. Warning! • Make sure that the function and operation of the rupture disk is not impeded through the installation.
  • Page 55 Proline Promass 84F, 84M A0009733 Promass F DN 250 1 = Indication label for the rupture disk, 2 = Transport protection, 3 = ½" NPT internal screw thread with 1" width across flats RUPTURE DISK 12,5 BAR +/-10%@80°C A0008788 Indication label for the rupture disk...
  • Page 56: Weight

    Proline Promass 84F, 84M approx. 42 AF 1" ½"-NPT All dimensions in [mm] Weight • Compact version: see table below • Remote version – Sensor: see table below – Wall-mount housing: 5 kg Weight data in [kg]. All values (weight) refer to devices with EN/DIN PN 40 flanges.
  • Page 57: Material

    Proline Promass 84F, 84M Material Transmitter housing: • Compact housing: – stainless steel 1.4301/304 – powder coated die-cast aluminium – Compact housing Ex d: stainless steel CF3M • Compact housing: – Wall-mount housing: powder coated die-cast aluminium – Remote field housing: powder-coated die-cast aluminium Connection housing, sensor (remote version): •...
  • Page 58: Material Load Curves

    Proline Promass 84F, 84M Process connections Process connections Promass F Material Flange according to EN 1092-1 (DIN 2501) / according to Alloy C-22 2.4602/N 06022, Stainless steel 1.4404/316L ASME B16.5 / JIS B2220 Flange DIN 11864-2 Form A (flat flange with groove) Stainless steel 1.4404/316L...
  • Page 59 Proline Promass 84F, 84M Promass F with flange connection according to ASME B16.5 Flange material: 1.4404/316L, Alloy C-22 [bar] Alloy C-22, Class 600 1.4404/316L, Class 600 Alloy C-22, Class 300 1.4404/316L, Class 300 Alloy C-22, Class 150 1.4404/316L, Class 150...
  • Page 60 Proline Promass 84F, 84M Promass F with Tri-Clamp process connection The Clamp connections (e.g. Tri-Clamp ISO2852, DIN32676) are suited up to a maximum pressure of 16 bar. As these operating limits also depend on the clamp and the seal used, their specifications have to be observed.
  • Page 61 Proline Promass 84F, 84M Promass M with flange connection according to EN 1092-1 (DIN 2501) Flange material: 1.4404/316L, titanium grade 2 [bar] PN 100 PN 63 PN 40 PN 16 -60 -40 -20 80 100 120 140 180 200 [°C] a0003293-en Promass M with flange connection according to ASME B16.5...
  • Page 62 Proline Promass 84F, 84M Promass M with flange connection to JIS B2220 Flange material: 1.4404/316L, titanium grade 2 [bar] -60 -40 -20 80 100 120 140 [°C] 180 200 a0003304-en Promass M with PVDF flange connection (to DIN 2501, according to ASME B16.5, JIS B2220)
  • Page 63 Proline Promass 84F, 84M Promass M with process connections for high pressure version Connector material: 1.4404/316L Material of thread connections (G 3/8", VCO with ½" SWAGELOK, NPT 3/8"): 14401/316 [bar] -60 -40 -20 80 100 120 140 180 200 [°C] a0004662-en Material of thread connections (NPT ½"): 1.4401/316...
  • Page 64: Process Connections

    Proline Promass 84F, 84M Promass M with flange connection to DIN 11864-2 Form A (flat flange with groove) Flange material: 1.4404/316L [bar] DN 8...40 DN 50...80 -60 -40 -20 80 100 120 140 180 200 [°C] a0004665-en Promass M with threaded hygienic connection to ISO 2853 Connection material: 1.4404/316L...
  • Page 65: Human Interface

    Ex approval Information about currently available Ex versions (ATEX, FM, CSA, IECEx, NEPSI) can be supplied by your Endress+Hauser Sales Centre on request. All explosion protection data are given in a separate documentation which is available upon request. C-tick mark The measuring system meets the EMC requirements of the Australian Communication and Media Authority (ACMA).
  • Page 66: Other Standards And Guidelines

    Proline Promass 84F, 84M Other standards and • EN 60529 guidelines Degrees of protection by housing (IP code) • EN 61010 Protection Measures for Electrical Equipment for Measurement, Control, Regulation and Laboratory Procedures) • ICE/EN 61326 "Emission in accordance with requirements for Class A" Electromagnetic compatibility (EMC- requirements) •...
  • Page 67: Suitability For Custody Transfer Measurement

    Mass Flow Meters" (1993-09-21). Promass MC approval for For liquids other than water [mm] Mass Volume 8 to 150 8 to 80 Ordering information The Endress+Hauser service organisation can provide detailed ordering information and information on the order codes on request. Endress+Hauser...
  • Page 68: Accessories

    Proline Promass 84F, 84M Accessories Various accessories, which can be ordered separately from Endress+Hauser, are available for the transmitter and the sensor. The Endress+Hauser service organisation can provide detailed information on the order codes of your choice. Documentation • Flow measuring technology (FA005D/06/en) •...
  • Page 69 Proline Promass 84F, 84M Endress+Hauser...
  • Page 70 Proline Promass 84F, 84M Endress+Hauser...
  • Page 71 Proline Promass 84F, 84M Endress+Hauser...
  • Page 72 Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel. +41 61 715 81 00 Fax +41 61 715 25 00 www.endress.com info@ii.endress.com TI067D/06/en/07.08 71076893 FM+SGML6.0 ProMoD...

This manual is also suitable for:

Proline promass 84m