Diagnostics
9.2 Diagnostic data and non-volatile SIMOTION data
● No distinction is made between upper-case and lower-case letters.
● It does not matter whether you use "\" or "/" in the path name.
Figure 9-6
Additional references
You will find detailed information on SIMOTION IT in the
Configuration Diagnostics Manual.
9.2.7

Delete/restore non-volatile SIMOTION data

9.2.7.1

Overview

Requirement
The non-volatile SIMOTION data have been backed up on the CF card by one of the following
methods:
● by system function (_savePersistentMemoryData), see also Section Operations and their
effect on the user memory (Page 90)
● manually by service selector switch / web server / DIAG button, see Section Backup of
diagnostic data and non-volatile SIMOTION data (Page 304).
Procedure
The non-volatile SIMOTION data are restored automatically during a module replacement, see
Section Replacing modules in the spare part scenario (Page 96). The non-volatile data can
also be restored manually (by manual operation).