8.2.3

Replacing DRIVE-CLiQ components

Requirement
DRIVE-CLiQ components not only support replacement in the switched-off state of the
machine/system (Power Off), but also replacement during operation. For this, the component
to be replaced must be at the end of the DRIVE-CLiQ line.
Removing DRIVE-CLiQ components
1. Deactivate the affected component or drive object.
2. Remove the DRIVE-CLiQ connector.
3. Remove the supply voltage of the component and uninstall the component.
Installing DRIVE-CLiQ components
1. Mount the component and reconnect the supply voltage.
2. Reconnect the DRIVE-CLiQ cable at the same location (port). The cable must have the
same length as the old one.
3. Activate the affected component or drive object.
Parameters for topology comparator and component replacement
In the expert list, you can use CU parameter p9906 to specify how the electronic rating plates
are compared for all the components of a Control Unit. The type of comparison can be changed
subsequently for each individual component by using p9907/p9908 or right-clicking in the
topology. All data on the electronic rating plate is compared by default.
● When p9909 = 1, the serial number and the hardware version of the new replacement
component are automatically transferred from the actual topology to the target topology,
and then saved in the non-volatile memory.
● When p9909 = 0, serial numbers and hardware versions are not automatically transferred.
The setting p9901 = 1 enables the spare parts / components replacement without tool
support to be carried out. The new serial number of the spare part is automatically transferred
from the actual topology to the target topology and saved in non-volatile memory. In order for
this to occur, the components that have been replaced must be of the same type and have the
same article number, such as "6SL3055-0AA0-5BA0". The last or last two digits of the article