Parameter assignment / addressing
6.6 Configuring an Ethernet subnet
4. Close the "Properties - PNxIE" dialog box with "OK".
5. Save and compile the modified hardware configuration.
6. Load the new hardware configuration to the SIMOTION D410‑2 via PROFIBUS DP/
Ethernet/PROFINET IO.
Shielded twisted pair cables are used for the networking. 4‑ and 8‑wire cables can be used for
10/100 Mbit/s.
Note
The TCP/IP timeout parameters are configured in HW Config by double-clicking the D410
module in the "Ethernet extended" tab.
Additional references
For additional information, see the
Networks Manual.
For further information about the cabling spectrum for Ethernet, see the
Communication IK PI Catalog.
6.6.3

Configuring Ethernet addresses in HW Config

Requirement
For configuration using Industrial Ethernet, SIMOTION D410‑2 must be provided with an IP
address, the subnet mask and the router address.
Note
Only one router may be configured.
Procedure
To configure and transfer Ethernet addresses to the D410‑2, proceed as follows:
1. Open your project.
2. Open HW Config. Double-click the interface to be configured (X127) to open the
"Properties" dialog box.
3. On the "General" tab, click the "Properties" button of the Ethernet interface. The "Properties
- Ethernet Interface" dialog is displayed.
4. Click the "New" button. The "New Industrial Ethernet" subnet dialog is displayed. In this
dialog box, you can change the name of the new subnet or confirm the default setting with
"OK".
136
SIMATIC NET, Industrial Twisted Pair, and Fiber Optic
Commissioning and Hardware Installation Manual, 01/2015
Industrial
SIMOTION D410-2