Siemens sinumerik 840d Programming Manual page 314

Hide thumbs Also See for sinumerik 840d:
Table of Contents

Advertisement

Path Traversing Behavior
9
9.3 Curve tables, CTABDEF, CTABEND, CTAB, CTABINV
840D
840D
NCU 571
NCU 572
NCU 573
Behavior at the edges of the curve table
Non-periodic curve table
If the leading value is outside the definition range,
the following value output is the upper or lower limit.
Periodic curve table
If the leading value is outside the definition range,
the leading value is evaluated modulo of the
definition range and the corresponding following
value is output.
9-314
810D
840Di
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) – 04.00 Edition
Following value
F
F
Definition range
L
Following value
F
Definition range
 Siemens AG 2000. All rights reserved
08.97
9
Leading
L
value
Leading
L
value

Hide quick links: