Setup Relating to DCU

Settings Relating to Signal Inputs (Input Config Menu)

The DCU parallel ports are assigned with the following priority sequence.
1. When external boxes are set, external boxes 1 to 4 are assigned from the
first parallel port.
2. When tally settings are carried out in the Router/Tally>Tally Enable menu,
tally inputs are assigned automatically.
In this menu, you set only the input ports which are unused after making the
above assignments.
To assign GPI inputs to DCU parallel input ports, display the DCU>Input
Config menu.
To display the Input Config menu
In the Engineering Setup menu, select VF5 'DCU' and HF1 'Input Config.'
The status area shows input port information.
Assigning a GPI input port
Use the following procedure.
1
In the DCU>Input Config menu, select what the setting applies to (DCU1
or DCU2) from the <DCU Select> group.
2
In the <Parallel Input Assign> group, press [GPI Input].
3
Using any of the following methods, assign the number of the GPI input to
the input port.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs to make the setting.
Knob
1
3
4
To confirm the assignment in step 3, press [GPI Input Set].
This assigns the GPI input, and this is reflected in the status area.
Parameter
Adjustment
Parallel Input
Input port
GPI Input
GPI inputs
Setting values
1 to 102
1 to 50
127