Saving Effects
When you recall an effect, the currently recalled effect is automatically saved
in a register. This is referred to as the auto save function.
You can disable the auto save function in a Setup menu.
By means of the following operation, you can also specify a register and save
an effect in it.
Saving an effect in a specified register
Specify the register using the numeric keypad control block. Use the following
procedure.
1
2
3
4
5
44
Saving Effects
Press the [EFF] button, turning it on.
This allocates the numeric keypad control block to keyframe operations.
Press the region selection button corresponding to the region for which you
want to save the register, turning it on.
See step 2 (page 22) of "Recalling a register."
Press the [STORE] button, turning it on.
With the numeric keypad, enter the number of the register in which you
want to save the effect.
To find an empty register, instead of entering a number, press the [.]
(period) button. To search for an empty register common to all currently
selectable regions, press the [.] button again.
To search for an empty register in the 100 range, press [1], [0], [0], [.]
(period) in this order. Similarly, to search for an empty register in the 200
range, press [2], [0], [0], [.] (period).
The register number appears in the display. If the number is followed by a
letter 'e' or 'E', this indicates the following.
e: The selected register is empty for the regions selected in step 2.
E: The selected register is empty for all selectable regions.
Press the [ENTER] button.
This saves the current effect in the specified register, and turns off the
[STORE] button. The [RCALL] button and [STORE STATS] button both
light.