11.4.2 Replace the inverter
11.5 Water inlet
11.5.1 Lubricating the rotating grommet low-pressure hose reel
11.5.2 Clean water filter.
102
English 5.906-736.0 Rev. 00 (07/15)
View with opened maintenance flap on the left
1 Inverter
Dismantle the maintenance flap on the left.
Disconnect the supply voltage and connection 24V AC
in the control cabinet.
Unscrew 4 screws from the bottom.
Replace the inverter. Observe the cable run with the
electrical connection!
NOTE
Mind the correct polarity upon the connection, as the in-
verter will otherwise be without any function!
1 Lubricating nipple rotating grommet
Grease the rotating grommet by means of a commer-
cially available grease gun.
1 Low-pressure hose drum
2 Hose water supply
3 Water filter