Fibre Channel Remote Copy Connections - HP xp12000 User Manual

Continuous access xp
Hide thumbs Also See for xp12000:
Table of Contents

Advertisement

5.
HP representative: If power sequence control cables are used, set the power select switch for the cluster
to LOCAL to prevent the host from powering off the MCU. Also ensure that the RCU will not be powered
off during Continuous Access XP operations. See
components" on page 107 for further information.
6.
HP representative: For Fibre Channel interface connections, install the Fibre Channel adapter features.
For serial interface connections, install the serial port adapter features. If the MCU and RCU are
multiplatform disk arrays, serial interfaces might be available, and additional serial port adapter
features might not be required.
7.
HP representative: Install the Continuous Access XP remote copy connections between MCUs and
RCUs. The user supplies this hardware (optical fibre cables, switches, and so on). See
remote copy
different storage clusters and switches to provide maximum flexibility and availability. Logical paths
between the MCU and RCU must be separate from logical paths between the host and RCU. For Fibre
Channel and serial interface connections, only Continuous Access XP activities (Sync and Async) can
share the same direct connect or switch zoned fibre remote copy connections (future support will
eliminate this restriction).

Fibre Channel remote copy connections

Figure 4
shows remote copy connection configurations for Fibre Channel interface Continuous Access XP
operations. The MCU and RCU of each Continuous Access XP pair must be connected via multimode
shortwave optical fibre cables. For multimode shortwave optical fibre cables, fibre cables up to 1.5 km in
length and up to two switches are required for distances greater than 0.5 km. For single-mode longwave
optical fibre cables between two switches, fibre cables up to 11 km in length can be used
(.5km+10km+.5km). Using DWDM between two FC switches can allow a distance of 80km or more.
Long-distance solutions are provided using approved channel extenders and communication lines.
Figure 4

Fibre Channel remote copy connections

NOTE:
For Fibre Channel interface connections, use the switches as ordinary switch connections. No
special settings are required for the XP12000/XP10000.
Fibre Channel interface connection provides the following configurations:
34
Continuous Access XP for the XP12000/XP10000
connections" on page 34 for remote copy configurations. Distribute paths between
"Powering off and on Continuous Access XP
"Fibre Channel

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp10000

Table of Contents