Continuous access xp
Hide thumbs Also See for xp12000:
Table of Contents

Advertisement

2.
In the RCU Operation pane, click MCU&RCU in the Switch Display box.
3.
In the CU number/Port tree, click the correct CU image. For this step, the list can be blank. You must
register and add RCUs to each CU image separately.
4.
In the MCU/RCU list, right-click. For registering RCU operations, the RCU does not have to be selected
on the list.
5.
In the pop-up menu, click RCU Operation, and click Add RCU. The Add RCU pane appears.
6.
Enter the RCU's S/N and the CU image's Controller ID, CU number, and SSIDs or Path Gr. ID. Enter the
value in hexadecimal within the range of 1 to FF for Path Gr. ID or use the default value. Up to 64 Path
Gr. IDs can be registered per subsystem. The MCU verifies the S/N when paths are established, and
verifies the SSIDs when volume pairs are created. If needed, add and delete SSIDs later using the Add
SSID pane (see
7.
Click the MCU and RCU ports from the drop-down lists. The MCU will not establish less than the
minimum number of paths as specified on the RCU Option pane (see
RCU
Option)" on page 71). If needed, you can add and delete paths later by using the Add Path pane
(see
"Adding and deleting logical paths for RCUs (Add Path/Delete
8.
Click Option to open the RCU Option pane. Click Cancel to cancel settings made on the Add RCU
pane.
9.
From the RCU Option pane, enter or select the settings for Minimum Paths, Maximum Initial Copy
Activity, and RIO MIH Time. For Fibre Channel interface, also specify the Path Blockade Watch setting.
10.In the RCU Option pane, click Set (even if you made no changes). Click Cancel to cancel the settings.
The list changes to the RCU Settings Parameter list.
11.The new RCU is displayed in the RCU Settings Parameter list. To check the path status for this RCU,
select the RCU, right-click, and click RCU Status. For more information about path status, see the
Troubleshooting chapter of the HP StorageWorks Command View XP user guide for XP Disk Arrays or
the HP StorageWorks XP Remote Web Console user guide for XP12000/XP10000.
NOTE:
After being set, options can be modified and canceled (see
settings" on page 77).
When the pair option is set (the RCU Option pane is closed), the list changes to the RCU Settings
Parameter list.
Figure 30

RCU Settings Parameter list

S/N: RCU serial number
SSID 1 to SSID 4: Selected SSID: SSID 1 to SSID 4
M-R Path: Channel type
Num. of Path: Number of the paths used
MCU Port 1 to MCU Port 8: Port number on the MCU side: 1 to 8
RCU Port 1 to RCU Port 8: Port number on the RCU side: 1 to 8
Min.Path: Minimum number of paths required for each RCU connected to the current MCU
Activity: Number of concurrent initial copy operations
MIH Time: Time value for the remote I/O (RIO) missing interrupt handler (MIH)
Path Watch: Time for monitoring blockade in the Fibre Channel paths on the MCU side
70
Continuous Access XP for the XP12000/XP10000
"Adding and deleting SSIDs for RCUs (Add SSID/Delete
Figure 30
shows the items in the RCU Settings Parameter list.
SSID)" on page 74).
"Modifying RCU options (Change
Path)" on page 73).
"Modifying parameters and deleting