NOTE:
Resyncing suspended LDEV pairs within a Continuous Access XP LUSE pair is not supported.
Figure 50
Pairresync pane
P-VOL: Port - G-ID - LUN of the selected volume.
NOTE:
volume. For details about external volumes, see the HP StorageWorks External Storage XP user
guide.
P-VOL Fence Level: Fence level.
• Never: Never fence the operation.
• Data: Fence when the MCU cannot successfully execute an update copy operation for any reason.
• Status: Fence only if the MCU cannot change the S-VOL status to the same status as the P-VOL. For
synchronous mode only.
When asynchronous pairs are created, Never is set automatically.
Initial Copy Parameters:
• Initial Copy Pace (From 1 to 15): Number of tracks for resume copy. The default is 15.
• Priority (From 1 to 256): Priority for resync operation, which determines order in which resync
operations are performed.
Asynchronous Parameters:
• Resume Range: When Group is selected, resync all split or suspended Continuous Access XP Async
pairs in the same group as the selected pair. When LU is selected, resync only the selected
Continuous Access XP Async pairs.
• Error Level: Error level for the Continuous Access XP Async pairs: Group or LU. This option is
available only when LU is selected for the Resume Range.
For more information about option parameters, see
the Paircreate
NOTE:
If an MCU or RCU is powered off and its backup batteries are fully discharged while Continuous
Access XP pairs are suspended, the P-VOL and S-VOL cylinder bitmaps are not retained. In this unlikely
case, the MCU and RCU mark all cylinders of all split or suspended Continuous Access XP volumes as
modified, so the MCU performs the equivalent of an entire initial copy operation when pairs are resynced.
100 Continuous Access XP for the XP12000/XP10000
If # is added to the end of the LDEV number, such as 00:3C#, the LDEV is an external
pane" on page 95.