Technical Specifications - HP ProLiant DL360 Generation9 Quickspecs

Gen9
Hide thumbs Also See for ProLiant DL360 Generation9:
Table of Contents

Advertisement

QuickSpecs

Technical Specifications

System Unit
Dimensions
(H x W x D)
Weight
(approximate)
Input
Requirements
BTU Rating
Power Supply
Output
System Inlet
Temperature
8 SFF and 10 SFF 1.7 x 17.1 x 27.5 inches (4.32 x 43.47 x 69.85 cm)
4 LFF - 1.7 x 17.1 x 29.5 inches (4.32 x 43.46 x 75.0 cm)
Maximum:
8 SFF CTO Server 33.3 lb. (15.31 kg) NOTE: Includes 2 SFF Option
(all hard drives,
for a total of 10 SFF HDD
power supply, and
processor
installed)
4 LFF CTO Server 37 lb. (16.78kg)
Minimum:
8SFF CTO Server 27 lb. (12.25 kg)
(one hard drive,
power supply, and
processor
installed)
4 LFF CTO Server 30.36 lb. (13.77 kg)
Range Line
100 to 120 VAC
Voltage
200 to 240 VAC
Maximum
For 800W Power Supply: 3207 BTU/hr (at 100 VAC), 3071
BTU/hr (at 200 VAC), 3112 BTU/hr (at 240 VAC) for China Only
For 500W Power Supply: 1979 BTU/hr (at 100 VAC), 1911
BTU/hr (at 200 VAC), 1965 BTU/hr (at 240 VAC) for China Only
Rated Steady-
For 1400W Power Supply: 1400W (at 240 VAC), 1400W (at 240
State Power
VAC
For 800W Power Supply: 800W (at 100 VAC), 800W (at 240
VAC), 800W (at 240 VAC) input for China only
For 500W Power Supply: 500W (at 100 VAC), 500W (at 240
VAC), 500W (at 240 VAC) input for China only
Maximum Peak
For 1400W Power Supply: 1400W (at 200 to 240 1VAC), 1400W
Power
(at 240 VAC) input for China only
For 800W Power Supply: 800W (at 100 to 127 VAC), 800W (at
200 to 240 1VAC), 800W (at 240 VAC) input for China only
For 500W Power Supply: 500W (at 100 to 127 VAC), 500W (at
200 to 240 VAC), 500W (at 240 VAC) input for China only
Standard
10° to 35°C (50° to 95°F) at sea level with an altitude derating of
Operating Support
1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level
to a maximum of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 20°C/hr (36°F/hr). The
upper limit and rate of change may be limited by the type and
number of options installed. Note: System performance during
standard operating support may be reduced if operating with a
fan fault or above 30°C (86°F).
Extended Ambient
For approved hardware configurations, the supported system
Operating Support
inlet range is extended to be: 5° to 10°C (41° to 50°F) and 35° to
40°C (95° to 104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m
(2953 ft) to a maximum of 3050 m (10,000 ft). The approved
hardware configurations for this system are listed at the URL:
http://www.hp.com/servers/ashrae
For approved hardware configurations, the supported system
inlet range is extended to be: 40° to 45°C (104° to 113°F) at sea
level with an altitude derating of 1.0°C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a maximum of 3050
c04375623 – DA – 15033 North America — Version 10 — September 28, 2015
HP ProLiant DL360 Generation9 (Gen9)
Page 49