Safety Data Sheet Océ 3155 Network Copier - Canon oce 31x5e Daily Maintenance

Table of Contents

Advertisement

Safety data sheet Océ 3155 Network Copier
PRODUCT SAFETY DATA SHEET
Model
Description
Max. process speed
Dimensions
Weight
Voltage
Frequenc y
Current-rated
Current-max
EPA
E
NERGY
* Power consumption,
Power consumption, operation
Power consumption, standb y
Mains connection
Safety class
Protection c l ass
Sound pressure le v el
(at operator/b ystander
position)
Sound po wer level
Radio interf erence
Radiation
Heat emission
Ozone emission
Room v olume
Room ventilation
Use sim ulation at random
operation
Consumab les
Additional saf ety inf o rmation
Copyright © 1998 Océ-T echnologies B.V . , Venlo, NL
The content of this safety data sheet is subject to the disclaimer of liability on page 103 of this manual.
Oc 3155 NC
Electrostatic network copier, console model, plain paper, organic photoconductive belt,
powder toner, automatic duplexing, Océ 3155 NC (Network Copier) = Océ 3155 + DAC
(Digital Access Controller).
52 A4 prints/min or 25 A3 prints/min
Width
1622 mm
Depth
Height
1280 mm
¨
S
TAR
48,7 W
auto-off
2000 W
Cable with plug
I
IP 20
Standb y:
38 dB(A)
49 dB(A)
Complies with FCC rules and regulations, part 15 class A
Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)
Standby 560 W (controller 32 W); in operation 2000 W (controller 40 W)
0,01 mg/min at continuous operation
Recommendation: min. 30 m
Recommendation: min. 15 m
For heat evacuation extra ventilation may be necessary.
Room volume and ventilation as recommended
Daily copy volume (much more than average)
Total worktime
Ozone concentrations:
- Time weighted average
- Peak
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone
Odour Perception Limit for ozone
Océ Master (Océ Material Safety Data Sheet E-193)
Océ F11 Toner (Océ Material Safety Data Sheet E-212)
Océ Copying Materials
This apparatus is suitable for processing recycling paper which complies with the
requirements of ENV 12281.
The ozone Þlter does not have to be replaced for keeping the ozone concentration in the
workplace below 0,04 mg/m
Listed according to standard UL 1950 and CAN/CSA-C22.2 No.950
885 mm
413 kg
120 V
208 V
60 Hz
60 Hz
16 A
9,8 A
20 A
14 A
560 W
(IEC 536) Protective earth connection
(IEC 529)
3
3
/h (natural ventilation)
3
(the life of the Þlter equals that of the apparatus).
LISTED 927F
INFORMATION
TECHNOLOGY
EQUIPMENT
E 69871
Number
Date
Digital Access Contr oller
220-240 V
60 Hz
9,2-8,8 A
14 A
In operation:
mainbody 59 dB(A);
incl. optionals 60 dB(A);
impulse ∆ L
= 5 dB(A)
i
mainbody 72 dB(A); incl. optionals 74 dB(A)
7500 A4
8 h
3
0,001 mg/m
3
0,003 mg/m
3
0,2 mg/m
3
0,04 mg/m
EPA
E
NERGY
E-690-b-US
March 1999
206 mm
437 mm
444 mm
14,9 kg
220-240 V
60 Hz
0,5 A
3 A
40 W
32 W
(0.0005 ppm)
(0.0015 ppm)
(0,1 ppm)
(0,02 ppm)
¨
S
TAR
113

Advertisement

Table of Contents
loading

Table of Contents