Microphone calibration file
Each UMIK-1 measurement microphone is individually calibrated to ensure accuracy. To download the
unique calibration file for your microphone, go to the
number. It is in the form xxx-yyyy and labelled on the microphone. Use "Save As" in your browser to save
the data to a text file – for example, UMIK-7001870.txt.
Then click on the Load File button and select your calibration file.
Once you have verified that this tab is correct, click the Proceed button.
5.3.3 Output & Levels tab
On the Output & Levels tab, set Output volume quite low.
Click on the Test button for the left channel and gradually increase the output volume until it is at a moderate
level, such that your voice would have to be raised to converse with someone sitting next to you.
Now increase the Input gain slider until the blue bar on the level meter reaches up into the green section, as
shown below.
Click again on the Test button for the left channel to stop the test signal. Then click on the Test button for the
right channel. If necessary, adjust Input gain or Output volume so that both channels are in the green.
When done, click the Proceed button.