HD Off:
Buzzer: Check box to enable buzzer when hard drive is off.
Email Notify: Check box to enable email notification when HD is off.
Network Alarm: Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Alarm Output: This will transmit a signal through one of the alarm outputs. It can be set to either "NONE"
(not active), "1", "2", "3", or "4".
Output Type: Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses "Enter" key.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.
Timeout Duration: The amount of time the buzzer sounds when the HD is off. Duration selectable from 1
to 150 seconds.
Figure 5-17 Alarm & Event Menu – Event - HD Off