8.15

Wiring Cover

1.
Remove the drawer front (refer to Section 8.2).
2.
With the drawer opened, remove the tub (refer to Section
8.6).
3.
Carefully release the four wiring cover clips, two on each
side, from the front lower section of the tub, taking care not
to damage them (Fig 1).
4.
Release the four clips on the underside of the tub that
attach the wiring cover to the motor assembly outer lock nut
(Fig 2).
5.
Pull the tub fully open and lift it up at the front (this makes it
easier to remove the wiring cover from the rear of the tub).
6.
The wiring cover may now be carefully moved forward and
downward to release it from the rear of the tub.
To reassemble, first ensure that the wiring harnesses, drain
hose and fill hose are located in their correct positions, then refit
in reverse manner.
Note: It may be found easier to remove and rotate the tub anti-
clockwise before removing the wiring cover.
8.16

Tub Disconnection

1.
Remove the drawer front (refer to Section 8.2).
2.
Remove the wiring cover (refer to Section 8.15).
3.
Disconnect the fill hose from the dispenser, or water
softener if fitted (water may drip).
4.
Disconnect the chassis harness plug from the controller.
5.
Remove the wiring cover and the element connector cover.
6.
Disconnect the element harness plug and earth wire from
the element plate.
7.
Unclip the drain hose cuff from the motor assembly, taking
care not to misplace the non-return flap valve.
8.
Unclip the drain hose, fill hose and the wiring loom from the
under side of the tub.
9.
Remove the tub.
Refit in reverse manner.
Note: When replacing a fill hose, drain hose or wiring harness,
transfer the link support clip markings from the old parts to the
new.