Removing The Wiring Cover; With The Tub Removed; With The Tub In Place - Fisher & Paykel DishDrawer DD60DI9 Service Manual

Hide thumbs Also See for DishDrawer DD60DI9:
Table of Contents

Advertisement

7 Refit the torx screws and reassemble the drawer front.

8.18 Removing the Wiring Cover

1 On the top tub, this can be done with the tub in place, or with the
tub removed.
2 The bottom tub will require to be removed from the chassis to gain
access to the securing screws and clips.

8.18.1 With the Tub removed:

1 Remove the tub as per instruction in section 8.13.
2 Remove the two torx screws retaining the wiring cover to the tub.
3 Carefully release the four wiring cover front clips, two on each
side, from under the front lower section of the tub. Take care not to
damage them.
4 Release the three clips on the underside of the tub that attaches the
wiring cover to the motor assembly.
5 Lift the wiring cover up and pull forward to disengage the rear
locating pins.
6 To reassemble, first ensure that the wiring harness, drain hoses and
fill hose are located in their correct positions
7 Refit cover in reverse manner.

8.18.2 With the Tub in place:

1 To remove the wiring cover with the tub in place, first remove the
drawer front.
2 Carefully release the four wiring cover front clips, two on each
side, from under the front lower section of the tub. Take care not to
damage them.
3 Release the three clips on the underside of the tub that attaches the
wiring cover to the motor assembly.
4 The wiring cover may now be carefully moved forward and
downward to release it from the rear of the tub.
5 To reassemble, first ensure that the wiring harness, drain hoses and
fill hose are located in their correct positions.
6 Then refit cover in reverse manner.