4. DISASSEMBLY
6. Agitator Motor replacement
1) Remove the agitator and belt as shown on
page 15.
2) Remove the 4 screws and pull out the Bracket.
3) Disconnect the 2 leads and remove the motor.
Note : This motor is marked '+' on one side
and ' – ' on the other side. Be sure to
connect properly. The wire color of '+'
is brown and ' - ' is blue.
4) To reinstall the Agitator Motor reverse the
steps above.
7. Micro Switch replacement
1) Remove the 1 screw and disconnect the 2
Bracket
2) To reinstall the Micro Switch reverse the
8. Fuse Break replacement
1) Lift the Fuse Break to the direction shown
2 Ieads
2 leads
2) To reinstall the Fuse Break reverse the
Positive
Pole (+)
Negative
Pole (-)
- 9 -
leads and remove the Micro Switch.
steps above.
and disconnect the 2 leads and then remove
the Fuse Break.
steps above.
MODEL 721.37060700
Micro
Switch
Fuse
Break