Push the new power supply partway into the bay, leaving the terminal
block at the side of the power supply exposed.
Using a Phillips screwdriver, remove the screw that secures the
plastic safety cover to the power supply, and then remove the cover.
Set the cover aside; you will replace it later.
Note the positions of the ground stud and of the positive and negative
power inputs. Make sure that the +DC cable is always connected
to the + terminal and that the -DC cable is always connected to the
- terminal.
DANGER
Make sure that the DC power source is off by switching
off the circuit breaker or disconnecting at the remote end
before you connect the terminal leads to the power supply.
Figure 15 "DC power supply input and ground stud location 8004DC"
(page 31)
shows the power supply input and ground stud location for
the 8004DC power supply.
ground stud location 8005DC" (page 32)
input and ground stud location for the 8005DC power supply.
Figure 15
DC power supply input and ground stud location 8004DC
Nortel Ethernet Routing Switch 8600
Quick Start
NN46205-310 01.01 Standard
4.1 21 December 2006
Installing a power module 31
Figure 16 "DC power supply input and
shows the power supply
Nortel Networks Confidential