IBM System x3650 Type 7979 Problem Determination And Service Manual page 90

Hide thumbs Also See for System x3650 Type 7979:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7979 and 1914 server," on page 79 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
System event/error log message
Memory Area non-recoverable over temperature
fault
Fan n Failure
n = the fan number
Fan n Fault
n = the fan number
Hard Drive n Fault
n = the hard disk drive number
Hard drive n removal detected.
n = the hard disk drive number
Power supply n removed
n = the power supply number
Power supply n fault
n = the power supply number
72
IBM System x3650 Type 7979 and 1914: Problem Determination and Service Guide
Action
1. Make sure that the fans are operating and are not obstructed.
2. Make sure that the air baffles are in place and correctly
installed.
3. Make sure that the server cover is installed and fully closed.
4. (Trained service technician only) Replace the system board.
1. Make sure that the connector on the fan is not damaged.
2. Make sure that the fan connector on the system board is not
damaged.
3. Make sure that the fan is fully installed (press down on the
fan).
4. Reseat fan n.
5. Replace fan n.
1. Make sure that the connector on the fan is not damaged.
2. Make sure that the fan connector on the system board is not
damaged.
3. Make sure that the fan is fully installed (press down on the
fan).
4. Reseat fan n.
5. Replace fan n.
1. Reseat hard disk drive n.
2. Replace hard disk drive n.
Reseat hard disk drive n.
1. Reseat power supply n.
2. Replace power supply n.
3. Replace the power backplane.
1. If the server power-on LED is lit, perform the following steps:
a. Reduce the server to the minimum configuration (see
"Solving undetermined problems" on page 76 for a
description of the miniimum configuration).
b. Reinstall the components you removed, one at a time,
restarting the server each time.
c. If the error reoccurs, the component you just reinstalled is
defective; replace the defective component.
2. Reseat the following components:
a. Power supply n
b. Power backplane
3. Replace the components listed in step 2, one at a time, in the
order shown, restarting the server each time.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3650 type 1914

Table of Contents