IBM System x3650 Type 7979 Problem Determination And Service Manual page 80

Hide thumbs Also See for System x3650 Type 7979:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7979 and 1914 server," on page 79 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
166-407-001
System Management: Failed.
BMC indicates failure in I
166-nnn-001
System Management: Failed.
Note: nnn indicates the failure type.
v 300 to 320: Self-test failure
v 400 to 420 (excluding 412, 414, and 415):
2
I
C bus test failure
166-412-001
System Management: Failed.
2
I
C bus failure.
166-414-001
System Management: Failed.
2
I
C bus failure.
62
IBM System x3650 Type 7979 and 1914: Problem Determination and Service Guide
Action
1. Disconnect all power cords and external cables
2
C bus test.
from the server, wait 30 seconds, reconnect the
power cords and cables, and retry the test.
2. Update the BMC firmware to the latest level.
3. Reseat the operator information panel cable.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Operator information panel assembly
b. (Trained service technician only) System
1. Disconnect all power cords and external cables
from the server, wait 30 seconds, reconnect the
power cords and cables, and retry the test.
2. Update the BMC firmware to the latest level.
3. (Trained service technician only) Replace the
system board.
1. Disconnect all power cords and external cables
from the server, wait 30 seconds, reconnect the
power cords and cables, and retry the test.
2. Update the BMC firmware to the latest level.
3. Reseat the power backplane.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Power backplane
b. (Trained service technician only) System
1. Disconnect all power cords and external cables
from the server, wait 30 seconds, reconnect the
power cords and cables, and retry the test.
2. Update the BMC firmware to the latest level.
3. Reseat the hard disk drive signal cable.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Hard disk drive backplane
b. (Trained service technician only) System
board
board
board

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3650 type 1914

Table of Contents