v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7979 and 1914 server," on page 79 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
166-415-001
System Management: Failed.
2
I
C bus failure.
180-xxx-000
Diagnostics LED failure.
180-xxx-001
Failed front LED panel test.
180-xxx-002
Failed diagnostics LED panel test.
180-361-003
Failed fan LED test.
180-xxx-003
Failed system board LED test.
Action
1. Disconnect all power cords and external cables
from the server, wait 30 seconds, reconnect the
power cords and cables, and retry the test.
2. Update the BMC firmware to the latest level.
3. Reseat the operator information panel cable.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Operator information panel assembly
b. (Trained service technician only) System
board
Run diagnostics panel LED test for the failing LED.
1. Reseat the operator information panel cable.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Operator information panel assembly
b. (Trained service technician only) System
board
Note: The light path diagnostics panel is part of the
operator information panel assembly.
1. Reseat the operator information panel cable.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Operator information panel assembly
b. (Trained service technician only) System
board
1. Reseat the fans.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Fans
b. (Trained service technician only) System
board
(Trained service technician only) Replace the system
board.
63
Chapter 2. Diagnostics