v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7979 and 1914 server," on page 79 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
020-xxx-000
Failed PCI Interface test.
030-xxx-099
Failed internal SCSI interface test.
035-285-001
Adapter Communication Error.
035-286-001
Adapter CPU Test Error.
035-287-001
Adapter Local RAM Test Error.
035-288-001
Adapter NVSRAM Test Error.
035-289-001
Adapter Cache Test Error.
035-292-001
Adapter Parameter Set Error.
035-230-001
Battery Low.
035-231-001
Abnormal Battery Temperature.
035-231-001
Battery Status Unknown.
58
IBM System x3650 Type 7979 and 1914: Problem Determination and Service Guide
Action
1. Reseat the riser-card assembly and the adapters
in the low-profile PCI slots.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Riser-card assembly
b. (Trained service technician only) System
board
(Trained service technician only) Replace the system
board.
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
1. Update the ServeRAID SAS controller firmware.
2. Reseat the ServeRAID SAS controller.
3. Replace the ServeRAID SAS controller.
Replace the battery module on the ServeRAID SAS
controller.
Replace the battery module on the ServeRAID SAS
controller.
Replace the battery module on the ServeRAID SAS
controller.