Crankcase And Tank Housing - Stihl MS 341 Shop Manual

Hide thumbs Also See for MS 341:
Table of Contents

Advertisement

9.1.4
Stop Buffer between
Crankcase and Tank
Housing
1
– Remove the crankcase from the
tank housing – b 12.9
: Use a suitable tool to pry the stop
buffer (1) out of the crankcase.
– Lubricate the new stop buffer with
STIHL Press Fluid OH 723 –
b 16.
– Push the stop buffer (1) into the
crankcase as far as stop.
Reassemble all other parts in the
reverse sequence.
1
: Use a suitable tool to pry the stop
buffer (1) out of the crankcase.
MS 341, MS 361, MS 361 C
1
2
– Lubricate the new stop buffer with
Press Fluid OH 723 – b 16.
: Push the stop buffer into the
housing until its groove (1)
engages over the inner housing
rib (2).
Reassemble all other parts in the
reverse sequence.
10.
Master Control /
Handle System
10.1
Switch Shaft
1
2
3
4
The Master Control lever moves the
switch shaft to select the required
function.
The following positions can be
selected with the Master Control
lever:
"STOP" (1) closes short circuit
contact, interrupts ignition
"RUN" (2) is the normal operating
position
"START" (3) is the starting throttle
position / choke shutter open (warm
start)
"CHOKE" (4) is the starting throttle
position / choke shutter closed (cold
start)
1
: Carefully ease the switch shaft
out of its left-hand mount (1) and
then pull it out of the right-hand
mount (arrow).
67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms 361

Table of Contents