Decompression Valve - Stihl MS 341 Shop Manual

Hide thumbs Also See for MS 341:
Table of Contents

Advertisement

6.8

Decompression Valve

1
– Remove the shroud – b 6.2
– Unscrew the decompression
valve (1).
Install in the reverse sequence.
– Fit the decompression valve and
tighten it down firmly – b 3.5
Reassemble all other parts in the
reverse sequence.
MS 341, MS 361, MS 361 C
7.
Ignition System
Exercise extreme caution when
troubleshooting or carrying out
maintenance and repair work on the
ignition system. The high voltages
that occur can cause serious or
even fatal accidents.
Troubleshooting on the ignition
system should always begin at the
spark plug – b 4.4
2
The electronic ignition system
basically consists of an ignition
module (1) and flywheel (2).
7.1
Ignition Module
The ignition module accommodates
all the components required to
control ignition timing. There are
two electrical connections on the
coil body:
: High voltage output (1) for
ignition lead
: Connector tag (2) for short
circuit wire
Testing in the workshop is limited to
a spark test.
A new ignition module must be
installed if no ignition spark is
obtained (after checking that wiring
and stop switch are in good
1
condition).
1
2
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms 361

Table of Contents