Installation method

Outdoor unit
When using the anchor bolt
Fix the unit on a flat, rigid floor using the anchor bolt.
(Anchor bolt : M10 x 4 points - separately purchased)
When using the rubber leg
Put the rubber leg to the outdoor unit leg.
Installation procedures
1. The piping of this unit can be connected to the right, left, and rear side.
- When you hit the area for piping connection slightly with a hammer, a hole is made.
Holes for piping connection
(4 points)
2. Open the front panel and separate it from the unit.
- Be careful of the power lines connected to control panel when removing.
3. Bend the connection pipe to an appropriate length using the spring bender depending upon the installation place.
- Allowable pipe length : Maximum 25m
- Allowable pipe drop distance : Maximum 15m
- Make no more than ten bending points on the pipe
❋ ❋ When the pipe length is in excess of the standard pipe length of 5m, add the refrigerant (R-22) of 40g for each additional
1m.
If the pipe is lengthened, the performance of the unit is degraded, and the service life is shortened. Therefore, the
pipe length should be as short as possible (less than 25m).
CAUTION
38
Mirage_AP50M0@_IBIM_EN_05323A-02.indd 38
Protective
piping cover
Piping
Drain hose
When the hole on the wall is lower than the
hole for piping connection.
Anchor bolt fixing dimensions
670mm
Outdoor unit leg
Rubber leg
Protective
piping cover
Piping
When the hole on the wall is higher than the hole
for piping connection.
Drain hose
2016-05-19 오후 1:27:24